§ 690-408. Fire suppression for equipment and transportation
Purdon's Pennsylvania Statutes and Consolidated StatutesTitle 52 P.S. Mines and MiningEffective: January 5, 2009
Effective: January 5, 2009
52 P.S. § 690-408
§ 690-408. Fire suppression for equipment and transportation
(4) Discharge nozzles of the system shall be positioned and aimed for maximum fire suppression effectiveness in the protected areas. Nozzles shall also be protected against the entrance of foreign materials, such as mud, coal dust or rock dust that could prevent proper discharge of suppressant agent.
(f) Manual actuators.--At least two manual actuators shall be provided, with at least one manual actuator at each end of the equipment. If the equipment is provided with an operator's compartment, one of the mechanical actuators shall be located in the compartment within easy reach of the operator. For stationary equipment, the two manual actuators shall be located with at least one actuator on the stationary equipment and at least one actuator a safe distance away from the equipment and in intake air.
Credits
2008, July 7, P.L. 654, No. 55, § 408, effective in 180 days [Jan. 5, 2009].
52 P.S. § 690-408, PA ST 52 P.S. § 690-408