6 CRR-NY 363-9.4NY-CRR

STATE COMPILATION OF CODES, RULES AND REGULATIONS OF THE STATE OF NEW YORK
TITLE 6. DEPARTMENT OF ENVIRONMENTAL CONSERVATION
CHAPTER IV. QUALITY SERVICES
SUBCHAPTER B. SOLID WASTES
PART 363. LANDFILLS
SUBPART 363-9. CLOSURE, POST-CLOSURE, AND CUSTODIAL CARE
6 CRR-NY 363-9.4
6 CRR-NY 363-9.4
363-9.4 Closure construction certification.
The construction certification required in section 360.16(j) of this Title must include a report that includes the following:
(a) the results of all CQA and CQC testing required in section 363-4.5 and Subpart 363-6 of this Part. The report must include documentation of any failed tests and all retesting performed and descriptions of procedures used to correct the improperly installed, damaged, or irregular material;
(b) record drawings noting any deviation from the approved closure plans; and
(c) a comprehensive narrative including, but not limited to, daily reports from the project engineer and a series of color photographs of major project features.
6 CRR-NY 363-9.4
Current through March 15, 2022
End of Document

IMPORTANT NOTE REGARDING CONTENT CURRENCY: The "Current through" date indicated immediately above is the date of the most recently produced official NYCRR supplement covering this rule section. For later updates to this section, if any, please: consult editions of the NYS Register published after this date; or contact the NYS Department of State Division of Administrative Rules at [email protected]. See Help for additional information on the currency of this unofficial version of NYS Rules.