21 CRR-NY 860.27NY-CRR

STATE COMPILATION OF CODES, RULES AND REGULATIONS OF THE STATE OF NEW YORK
TITLE 21. MISCELLANEOUS
CHAPTER XVIII. DELAWARE RIVER BASIN COMMISSION
SUBCHAPTER B. WATER QUALITY REGULATIONS
PART 860. WATER QUALITY STANDARDS FOR THE DELAWARE RIVER BASIN (ARTICLE 3)
INTERSTATE STREAMS—TIDAL
21 CRR-NY 860.27
21 CRR-NY 860.27
860.27 Zone 2.
(a) Description.
Zone 2 is that part of the Delaware River extending from the head of tidewater at Trenton, NJ, RM (River Mile) 133.4 (Trenton-Morrisville Toll Bridge) to RM 108.4 below the mouth of Pennypack Creek, including the tidal portions of the tributaries thereof.
(b) Water uses to be protected.
The quality of zone 2 waters shall be maintained in a safe and satisfactory condition for the following uses:
(1)
(i) public water supplies after reasonable treatment;
(ii) industrial water supplies after reasonable treatment;
(iii) agricultural water supplies;
(2)
(i) maintenance and propagation of resident fish and other aquatic life;
(ii) passage of anadromous fish;
(iii) wildlife;
(3)
(i) recreation; and
(4) navigation.
(c) Stream quality objectives.
(1) Dissolved oxygen:
(i) 24-hour average concentration shall not be less than 5.0 mg/l; and
(ii) during the periods from April 1st to June 15th, and September 16th to December 31st, the dissolved oxygen shall not have a seasonal average less than 6.5 mg/l.
(2) Temperature.
Shall not exceed:
(i) 5°F (2.8°C) above the average 24-hour temperature gradient displayed during the 1961-66 period; or
(ii) a maximum of 86°F (30.0°C), whichever is less. (See section 861.12[f][3] of this Title.)
(3) pH.
Between 6.5 and 8.5 inclusive, unless outside this range due to natural conditions.
(4) Phenols.
Maximum 0.005 mg/l, unless exceeded due to natural conditions.
(5) Threshold odor number.
Not to exceed 24 at 60°C.
(6) Synthetic detergents (M.B.A.S.).
Maximum 30-day average 0.5 mg/l.
(7) Radioactivity:
(i) alpha emitters, maximum 3 pc/l (picocuries per liter); and
(ii) beta emitters, maximum 1,000 pc/l.
(8) Bacteria.
(i) Fecal Coliform. Maximum geometric average 200 per 100 milliliters.
(ii) Enterococcus. Maximum geometric average 33 per 100 milliliters.
(9) Total dissolved solids.
Not to exceed:
(i) 133 percent of background; or
(ii) 500 mg/l, whichever is less.
(10) Turbidity.
Unless exceeded due to natural conditions:
(i) maximum 30-day average 40 units;
(ii) maximum 150 units; and
(iii) except above RM 117.81 during the period May 30th to September 15th when the turbidity shall not exceed 30 units.
(11) Alkalinity.
Between 20 and 100 mg/l.
(12) Chlorides.
Maximum 15-day average 50 mg/l.
(13) Hardness.
Maximum 30-day average 95 mg/l.
(14) Toxic pollutants.
(i) Applicable MCLs and criteria to protect the taste and odor of ingested water and fish are presented in Tables 3 and 4 (section 860.30(c)(11).
(ii) Applicable freshwater stream quality objectives for the protection of aquatic life are presented in Table 5 (section 860.30(c)(11).
(iii) Applicable freshwater stream quality objectives for the protection of human health are presented in Tables 6 and 7 (section 860.30(c)(11).
(d) Effluent quality requirements.
(1) All discharges shall meet the effluent quality requirements of this Part.
(2) The carbonaceous oxygen demand from all outfalls in the zone (exclusive of storm water bypass) shall not exceed that assigned by commission regulations.
21 CRR-NY 860.27
Current through July 15, 2021