261.57 Warning tag: Class A condition.
(a) A Class A condition presents an immediate hazard requiring the operator to shut off the gas and lock the meter, unless the operator can effectively isolate the affected area from the rest of the system.
(b) Class A conditions include, but are not limited to:
(1) any leaking gas piping inside the building which cannot be stopped by temporary or permanent repair means;
(2) any space or water heating appliance that is not properly venting and is discharging carbon monoxide;
(3) any venting system, used to convey flue gases, that is defective, obstructed or inoperable; and
(4) heat exchangers which are corroded or cracked beyond repair or blocked and which cause products of combustion to enter the warm air distribution system.
16 CRR-NY 261.57
Current through March 31, 2022
End of Document |
IMPORTANT NOTE REGARDING CONTENT CURRENCY: JULY 31, 2023, is the date of the most recently produced official NYCRR supplement covering this rule section. For later updates to this section, if any, please: consult editions of the NYS Register published after this date; or contact the NYS Department of State Division of Admisnistrative Rules at [email protected]. See Help for additional information on the currency of this unofficial version of the NYS Rules.