16 CRR-NY 255.945NY-CRR

STATE COMPILATION OF CODES, RULES AND REGULATIONS OF THE STATE OF NEW YORK
TITLE 16. DEPARTMENT OF PUBLIC SERVICE
CHAPTER III. GAS UTILITIES
SUBCHAPTER C. SAFETY
PART 255. TRANSMISSION AND DISTRIBUTION OF GAS
TRANSMISSION PIPELINE INTEGRITY MANAGEMENT
16 CRR-NY 255.945
16 CRR-NY 255.945
255.945 Measuring program effectiveness.
(a) General.
An operator must include in its integrity management program methods to measure whether the program is effective in assessing and evaluating the integrity of each covered pipeline segment and in protecting the high consequence areas. These measures must include the four overall performance measures specified in ASME/ANSI B31.8S (as described in section 10.3 of this Title), section 9.4, and the specific measures for each identified threat specified in ASME/ANSI B31.8S, Appendix A. An operator must submit the four overall performance measures as part of the annual report required by 49 CFR section 191.17.
(b) External corrosion direct assessment.
In addition to the general requirements for performance measures in subdivision (a) of this section, an operator using direct assessment to assess the external corrosion threat must define and monitor measures to determine the effectiveness of the ECDA process. These measures must meet the requirements of section 255.925 of this Part.
16 CRR-NY 255.945
Current through March 31, 2022