56-4.5 Air sample log.
A project air sample log shall be created by the firm performing the project air sampling and it shall contain the following information for all area air samples collected on the asbestos project:
(a) name of the firm and the certified air sampling technician performing the project air sampling, per workshift or day for all area air samples collected;
(b) dates of project air sample collection, per workshift or day of area air samples, with appropriate reference to the regulated abatement work area to which the air samples apply;
(c) sample locations sketch, identifying all project air sample locations, per workshift or day of area air samples. If identical locations are utilized for each workshift or day of area samples collected throughout a sub-phase of the asbestos project (IIA, IIB or IIC), only one sketch is required for all workshift or day of area samples collected for that specific sub-phase of the asbestos project;
(d) the identifying information for each area air sample collected;
(e) sampling time (24-hour clock) and duration for each area air sample collected;
(f) flow rate primary or secondary calibration device identification number, method of flow rate primary or secondary device calibration and date of last calibration, per workshift or day of area air samples;
(g) flow rate of sampling pumps with pre- and post-calibration listed for each area air sample collected; and
(h) chain of custody for each workshift or day of area air samples.