6 CRR-NY 232.17NY-CRR

OFFICIAL COMPILATION OF CODES, RULES AND REGULATIONS OF THE STATE OF NEW YORK
TITLE 6. DEPARTMENT OF ENVIRONMENTAL CONSERVATION
CHAPTER III. AIR RESOURCES
SUBCHAPTER A. PREVENTION AND CONTROL OF AIR CONTAMINATION AND AIR POLLUTION
PART 232. PERCHLOROETHYLENE DRY CLEANING FACILITIES
6 CRR-NY 232.17
6 CRR-NY 232.17
232.17 Equivalency.
(a) Any person requesting that use of alternative equipment or procedures be considered by the department, as equivalent to the requirements under section 232.6 of this Part, must collect, verify and submit to the department the following information to show that the alternative achieves equivalent emission reductions:
(1) diagrams, as appropriate, illustrating the emission control technology, its operation and integration into or function with closed-loop third generation machines and dry-to-dry vented second generation machines;
(2) information indicating the levels of vented perc emissions from dry-to-dry second generation machines during each portion of the dry cleaning cycle with and without the use of alternative emission control technology that is being tested, and information indicating the levels of fugitive emissions from all equipment;
(3) information detailing operation and maintenance requirements and appropriate testing parameters consistent with sections 232.7 and 232.8 of this Part;
(4) information demonstrating that the environmental impacts are consistent with sections 232.9 and 232.10 of this Part;
(5) documentation on solvent mileage (pounds of articles cleaned per gallon of solvent added) achieved with and without use of the alternative emission control technology. Solvent mileage data must be of continuous duration for at least one year under the conditions of a typical dry cleaning operation. This information on solvent mileage must be accompanied by information on the design, configuration, operation, and maintenance of the specific dry cleaning system from which the solvent mileage information was obtained; and
(6) information indicating the level of emissions required in paragraph (2) of this subdivision and information which demonstrates emission reductions equal to or greater than those stated in section 232.6 of this Part for equivalent technology.
(b) For the purpose of determining equivalency of control of emissions to those required under this Part, the department will evaluate whether the alternative control technology has been demonstrated adequately. If the demonstration is adequate, the alternative technology will be eligible for certification under the provisions of section 232.13 of this Part.
(c) Any decision made by the department in accordance with subdivisions (a) and (b) of this section is contingent upon review and approval by EPA.
6 CRR-NY 232.17
Current through August 31, 2017
End of Document© 2017 Thomson Reuters. No claim to original U.S. Government Works.