Home Table of Contents

§ 612.65. Attaching Utilities to Cross-Drainage Structures.

23 CA ADC § 612.65Barclays Official California Code of Regulations

Barclays California Code of Regulations
Title 23. Waters
Division 2. Department of Water Resources
Chapter 6. Encroachments
Article 6. Requirements for Specific Types of Encroachments
23 CCR § 612.65
§ 612.65. Attaching Utilities to Cross-Drainage Structures.
(a) The applicant shall follow all the following specific requirements for attaching utilities to cross-drainage structures:
(1) Anchor bolt locations shall not intercept the critical reinforcing steel of the cross-drainage structure.
(2) After installation, exposed metal surfaces shall be cleaned and primed with paint of the same quality as that used for shop coat.
(3) Utilities shall not be permitted to be installed inside the cross-drainage structure.
(4) Lateral supports for the utility shall withstand a seismic loading of no less than 0.5g (Include Pipe Material and Content inside the pipe in the calculation). Spacing of supports shall not exceed a maximum of twelve (12) feet.
(5) Anchor bolts shall be hot-dipped galvanized double wedge conforming to Federal Specification FF-S-325 Amendment No. 3, Group II, Type 4, Class 1; and shall be installed according to the manufacturer's instructions, or equivalent.

Credits

Note: Authority cited: Section 12899.9, Water Code. Reference: Sections 12899, 12899.1(a), 12899.1(c) and 12899.2, Water Code.
History
1. New section filed 4-22-2015; operative 7-1-2015 (Register 2015, No. 17).
This database is current through 4/12/24 Register 2024, No. 15.
Cal. Admin. Code tit. 23, § 612.65, 23 CA ADC § 612.65