Home Table of Contents

§ 30333.1. Operating and Emergency Procedures.

17 CA ADC § 30333.1Barclays Official California Code of Regulations

Barclays California Code of Regulations
Title 17. Public Health
Division 1. State Department of Health Services (Refs & Annos)
Chapter 5. Sanitation (Environmental) (Refs & Annos)
Subchapter 4. Radiation
Group 3. Standards for Protection Against Radiation
Article 6. Special Requirements for Radiographic Operations in Industrial Radiography
17 CCR § 30333.1
§ 30333.1. Operating and Emergency Procedures.
(a) Each user shall establish, implement, maintain and keep current written operating and emergency procedures which shall include detailed instructions in at least the following matters:
(1) The handling and use of radiographic exposure devices and the manner of employment to control and limit radiation exposures to individuals;
(2) Methods and occasions for conducting radiation surveys;
(3) Methods and occasions for controlling access to radiography areas;
(4) Methods and occasions for locking and securing radiographic exposure devices, transport and storage containers and sealed sources;
(5) Personnel monitoring and the use of personnel monitoring devices;
(6) Steps that must be taken immediately by radiographic personnel in the event a pocket dosimeter is found to be off scale or an alarm ratemeter alarms unexpectedly;
(7) Transporting sealed sources to field locations, including packing of radiographic exposure devices and storage containers in the vehicle, placarding of vehicles when needed and control of the sealed sources during transportation;
(8) Procedures in the event of an accident, including sealed source handling, minimizing radiation exposure to individuals, and notifying proper persons;
(9) Maintenance of records;
(10) The inspection, maintenance, and operability checks of radiographic exposure devices, survey instruments, transport and storage containers and source changers; and
(11) Source recovery procedures if licensee will perform source recovery.
(b) Each user shall maintain a copy of current operating and emergency procedures until the Department terminates the license. Superseded material shall be retained for three years after the change is made.

Credits

Note: Authority cited: Sections 114975, 115000 and 131200, Health and Safety Code. Reference: Sections 114965, 114970, 115000, 115060, 115230, 115235, 131050, 131051 and 131052, Health and Safety Code.
History
1. Renumbering and amendment of former Section 30333(b) to Section 30333.2 filed 7-7-86; effective thirtieth day thereafter (Register 86, No. 28). For prior history, see Register 72, No. 42.
2. Amendment of section and Note filed 4-11-2008; operative 5-11-2008 (Register 2008, No. 15).
3. New subsection (b) and amendment of Note filed 12-30-2014; operative 4-1-2015 (Register 2015, No. 1).
This database is current through 4/26/24 Register 2024, No. 17.
Cal. Admin. Code tit. 17, § 30333.1, 17 CA ADC § 30333.1