§ 4002.9. Hydrogen Gas-Measuring Devices (3.39).
A.4. Type Evaluation.--The National Type Evaluation Program (NTEP) or California Type Evaluation Program (CTEP) will accept for type evaluation only those hydrogen gas-measuring devices that comply with all applicable requirements of this article.
S.5.2. Location of Accuracy Class 2.0, 3.0, 5.0, 7.0, and 10.0 Information--An additional Accuracy Class statement shall be placed adjacent to the quantity display on the face for the dispenser and shall be conspicuously, legibly, and indelibly marked with a statement such as “The Accuracy Class of this dispenser is XX.0 and represents the accuracy of the delivery expressed as a plus or minus percentage of the delivered quantity”. The lettering shall be in Helvetica or Arial Bold font type, in all capitals, and no less than 3/16 inch (0.48 cm) in height.
Note: The XX.0 is the Accuracy Class as stated on the NTEP Certificate of Conformance or CTEP Certificate of Approval and is part of the identification information required in paragraph S.5. The rating represents the allowable limits of error expressed as a plus and minus value.
EXAMPLE:
T.2. Tolerances. The tolerances for hydrogen gas-measuring devices are listed in Table T.2. Accuracy Classes and Tolerances for Hydrogen Gas-Measuring Devices.
Table T.2. Accuracy Classes and Tolerances for Hydrogen Gas-Measuring Devices Used to Measure Hydrogen Gas as a Vehicle Fuel.
Accuracy Class.
Acceptance Tolerance.
Maintenance Tolerance.
2.0
1.5 %
2.0 %
3.0
2.0 %
3.0 %
5.0
4.0 %
5.0 %
7.0
5.0 %
7.0 %
10.0
5.0 %
10.0 %
In Table T.2., above, the tolerance values for Accuracy Class 10.0 hydrogen gas-measuring devices are applicable to devices installed prior to January 1, 2018.

Credits

Note: Authority cited: Sections 12027 and 12107, Business and Professions Code. Reference: Section 12107, Business and Professions Code.
History
1. New section filed 6-16-2014; operative 6-16-2014 pursuant to Government Code section 11343.4(b)(3) (Register 2014, No. 25).
2. Amendment filed 1-23-2020; operative 1-23-2020 pursuant to Government Code section 11343.4(b)(3) (Register 2020, No. 4).
This database is current through 4/26/24 Register 2024, No. 17.
Cal. Admin. Code tit. 4, § 4002.9, 4 CA ADC § 4002.9
End of Document