Home Table of Contents

Appendix VI Recommended Technologies to Achieve Deactivation of Characteristics in Section 6626...

22 CA ADC Div. 4.5 Ch. 18 App. VIBarclays Official California Code of Regulations

Barclays California Code of Regulations
Title 22. Social Security
Division 4.5. Environmental Health Standards for the Management of Hazardous Waste
Chapter 18. Land Disposal Restrictions
22 CCR Div. 4.5 Ch. 18 App. VI
Appendix VI Recommended Technologies to Achieve Deactivation of Characteristics in Section 66268.42
The treatment standard for many characteristic wastes is stated in the section 66268.40 Table of Treatment Standards as “Deactivation and meet UTS.” USEPA has determined that many technologies, when used alone or in combination, can achieve the deactivation portion of the treatment standard. Characteristic wastes that are not managed in a facility regulated by the federal Clean Water Act (CWA) or in a federal CWA-equivalent facility, and that also contain underlying hazardous constituents (see section 66260.10) shall be treated not only by a “deactivating” technology to remove the characteristic, but also to achieve the universal treatment standards (UTS) for underlying hazardous constituents. The following appendix presents a partial list of technologies, utilizing the five letter technology codes established in section 66268.42 Table 1, that may be useful in meeting the treatment standard. Use of these specific technologies is not mandatory and does not preclude direct reuse, recovery, and/or the use of other pretreatment technologies, provided deactivation is achieved and underlying hazardous constituents are treated to achieve the UTS.
Waste Code/Subcategory
Nonwastewaters
Wastewaters
D001 Ignitable Liquids based
RORGS
n.a.
on 66261.21(a)(1) - Low TOC
INCIN
Nonwastewater Subcategory
WETOX
(containing 1% to <10% TOC)
CHOXD
BIODG
D001 Ignitable Liquids based
n.a.
RORGS
on 66261.21(a)(1) - Ignitable
INCIN
Wastewater Subcategory
WETOX
(containing <1% TOC)
CHOXD
BIODG
D001 Compressed Gases based on
RCGAS
n.a.
66261.21(a)(3)
INCIN
FSUBS
ADGAS fb. INCIN ADGAS fb. (CHOXD; or CHRED)
D001 Ignitable Reactives based
WTRRX
n.a.
on 66261.21 (a)(2)
CHOXD
CHRED
STABL
INCIN
D001 Ignitable Oxidizers based
CHRED
CHRED
on 66261.21(a)(4)
INCIN
INCIN
D002 Acid Subcategory based on
RCORR
NEUTR
66261.22(a)(1) with pH less
NEUTR
INCIN
than or equal to 2
INCIN
D002 Alkaline Subcategory
NEUTR
NEUTR
based on 66261.22(a)(1) with
INCIN
INCIN
pH greater than or equal to 12.5
D002 Other Corrosives based on
CHOXD
CHOXD
66261.22(a)(2)
CHRED
CHRED
INCIN
INCIN
STABL
D003 Water Reactives based on
INCIN
n.a.
66261.23(a)(2), (3), and (4)
WTRRX
CHOXD
CHRED
D003 Reactive Sulfides based
CHOXD
CHOXD
on 66261.23(a)(5)
CHRED
CHRED
INCIN
BIODG
STABL
INCIN
D003 Explosives based on
INCIN
INCIN
66261.23(a)(6), (7), and (8)
CHOXD
CHOXD
CHRED
CHRED
BIODG
CARBN
D003 Other Reactives based on
INCIN
INCIN
66261.23(a)(1)
CHOXD
CHOXD
CHRED
CHRED
BIODG
CARBN
K044 Wastewater treatment
CHOXD
CHOXD
sludges from the manufacturing
CHRED
CHRED
and processing of explosives
INCIN
BIODG
CARBN
INCIN
K045 Spent carbon from the
CHOXD
CHOXD
treatment of wastewaters
CHRED
CHRED
containing explosives
INCIN
BIODG
CARBN
INCIN
K047 Pink/red water from TNT
CHOXD
CHOXD
operations
CHRED
CHRED
INCIN
BIODG
CARBN
INCIN
NOTE: “n.a.” stands for “not applicable”; “fb.” stands for “followed by”.

Credits

NOTE: Authority cited: Sections 208, 25150, 25159 and 25179.6, Health and Safety Code. Reference: Sections 25150, 25159, 25159.5 and 25179.6, Health and Safety Code; 40 CFR Part 268 Appendix VI.
This database is current through 4/26/24 Register 2024, No. 17.
Cal. Admin. Code tit. 22, Div. 4.5 Ch. 18 App. VI, 22 CA ADC Div. 4.5 Ch. 18 App. VI
End of Document