Home Table of Contents

§ 1604. Test Methods for Specific Appliances.

20 CA ADC § 1604BARCLAYS OFFICIAL CALIFORNIA CODE OF REGULATIONS

Barclays Official California Code of Regulations Currentness
Title 20. Public Utilities and Energy
Division 2. State Energy Resources Conservation and Development Commission
Chapter 4. Energy Conservation
Article 4. Appliance Efficiency Regulations (Refs & Annos)
20 CCR § 1604
§ 1604. Test Methods for Specific Appliances.
(a) Refrigerators, Refrigerator-Freezers, and Freezers.
(1) The test methods for non-commercial refrigerators designed for the refrigerated storage of food at temperatures above 32oF and below 39oF, configured for general refrigerated food storage, non-commercial refrigerator-freezers, miscellaneous refrigeration products, and non-commercial freezers are 10 C.F.R. sections 430.23(a) (Appendix A to subpart B of part 430) and 430.23(b) (Appendix B to subpart B of part 430).
(2) The test methods for commercial refrigerators, commercial refrigerator-freezers, and commercial freezers are shown in Table A-1.
Table A-1
Commercial Refrigerator, Refrigerator-Freezer, and
Freezer Test Methods
Appliance
Test Method
 
Automatic commercial ice makers
10 C.F.R. sections 431.133 and 431.134
Refrigerated bottled or canned
10 C.F.R. sections 431.293 and 431.294
beverage vending machines
 
Refrigerated buffet and preparation
ANSI/ASTM F2143-01
tables
 
Other commercial
10 C.F.R. sections 431.63 and 431.64
refrigerators, refrigrator-freezers,
and freezers, with doors
 
Other commercial
10 C.F.R. sections 431.63 and 431.64
refrigerators, refrigerator-freezers,
and freezers, without doors
 
Walk-in coolers and
10 C.F.R. sections 431.303 and 431.304
walk-in freezers
(3) When a refrigerator, refrigerator-freezer, or freezer can be operated using either alternating current electricity or one or more other sources of primary power, the test shall be performed using alternating current electricity only.
(4) The test method for water dispensers is EPA Energy Star Program Requirements for Bottled Water Coolers (2004).
Exception to Section 1604(a)(4): Water dispensers equipped with an integral, automatic timer. Water dispensers equipped with an integral, automatic timer shall not be tested using Section 4)D, “Timer Usage,” of the referenced test method.
(b) Room Air Conditioners, Room Air Conditioning Heat Pumps, Packaged Terminal Air Conditioners, and Packaged Terminal Heat Pumps. The test methods for room air conditioners, room air-conditioning heat pumps, packaged terminal air conditioners, and packaged terminal heat pumps are shown in Table B-1.
Table B-1
Room Air Conditioner, Room Air-Conditioning Heat Pump,
Packaged Terminal Air Conditioner, and Packaged Terminal
Heat Pump Test Methods
Appliance
Test Method
 
Room air conditioners and room
10 C.F.R. section 430.23(f) (Appendix F
air-conditioning heat pumps
to subpart B of part 430)
 
Packaged terminal air conditioners
10 C.F.R. sections 431.95 and 431.96
and packaged terminal heat pumps
 
(c) Central Air Conditioners, Air Filters, and Heat Pump Water-Heating Packages.
(1) The test methods for central air conditioners are shown in Table C-1.
(2) For each basic model of central air conditioner and heat pump, test the individual model and combination as required in 10 C.F.R. section 429.16(b)(2).
Table C-1
Central Air Conditioner Test Methods
Applicance
Test Method
 
Computer Room Air Conditioners
evaporatively cooled
ANSI/ASHRAE 127-2001
10 C.F.R. sections 431.95 and 431.96
air-cooled, glycol-cooled,
water-cooled
Other electric-powered unitary
air-conditioners and electric-powered
heat pumps
air-cooled air conditioners and
air-source heat pumps
<65,000 Btu/hr, single-phase
10 C.F.R. section 430.23(m) (Appendix
M to subpart B of part 430)
<65,000 Btu/hr, three-phase
10 C.F.R. sections 431.95 and 431.96
≥ 65,000 and < 760,000 Btu/hr
10 C.F.R. sections 431.95 and 431.96
evaporatively cooled air
conditioners
< 240,000 Btu/hr
10 C.F.R. sections 431.95 and 431.96
water-cooled air conditioners and
water-source heat pumps
< 240,000 Btu/hr
10 C.F.R. sections 431.95 and 431.96
ground water-source heat pumps
ARI/ISO-13256-1:1998
ground-source closed-loop heat
pumps
ARI/ISO-13256-1:1998
Variable Refrigerant Flow
Multi-split Systems
10 C.F.R. sections 431.95 and 431.96
Single Package Vertical Air
10 C.F.R. sections 431.95 and 431.96
Conditioners and Single Package
Vertical Heat Pumps
ANSI Z21.40.4-1996 as modified
Gas-fired air conditioners and
by CEC, Efficiency Calculation Method
gas-fired heat pumps
for Gas-Fired Heat Pumps as a New
Compliance Option (1996)
 
(3) Air Filters. The test methods for air filters are shown in Table C-2.
Table C-2
Air Filter Test Methods
Manufacturers shall test small, medium, and large size filters for each grade.
(4) Heat Pump Water Heating Packages. Heat pump water heating packages shall be tested using ANSI/AHRI 550-590 (I-P) 2011. The heating capacity tests shall be conducted at ambient temperature of each 47oF and 17oF and a leaving water temperature of 120oF. If the package is capable of cooling, it shall be tested at an ambient temperature of 95oF and a leaving water temperature of 44oF.
(d) Portable Air Conditioners, Evaporative Coolers, Ceiling Fans, Ceiling Fan Light Kits, Whole House Fans, Residential Exhaust Fans, Dehumidifiers, and Residential Furnace Fans.
The test methods for portable air conditioners, evaporative coolers, ceiling fans, ceiling fan light kits, whole house fans, residential exhaust fans, dehumidifiers, and residential furnace fans are shown in Table D-3.
Table D-3
Portable Air Conditioner, Ceiling Fan, Ceiling Fan Light Kit, Evaporative Cooler, Whole House Fan, Residential Exhaust Fan, Dehumidifier, and Residential Furnace Fan Test Methods
(e) Gas and Oil Space Heaters and Electric Residential Boilers.
(1) Gas Space Heaters and Oil Space Heaters. The test methods for gas space heaters and oil space heaters are shown in Table E-1.
(2) Natural Gas and LPG Space Heaters. Gas space heaters intended for use either with natural gas or LPG may be tested with natural gas and the results applied to both fuel types.
(3) Combination Space-Heating and Water-Heating Appliances. The test method for combination space-heating and water-heating appliances is ANSI/ASHRAE 124-2007.
Table E-1
Gas and Oil Space Heater Test Methods
(f) Water Heaters.
(1) Residential Water Heaters: The test method for residential water heaters is 10 C.F.R. section 430.23(e) (Appendix E to subpart B of part 430).
(2) Water heaters that are Regulated Under subpart G of 10 C.F.R. part 431.
The test methods for water heaters that are regulated under subpart G of 10 C.F.R. part 431 are found at 10 C.F.R. sections 431.105 and 431.106.
(3) Dual-Fuel Models. Water heaters intended for use either with natural gas or LPG may be tested with natural gas and the results applied to both fuel types.
(g) Pool Heaters, Portable Electric Spas, Pumps, Residential Pool Pump and Motor Combinations, and Replacement Residential Pool Pump Motors.
(1) Test Methods for Pool Heaters.
The test method for fossil fuel-fired pool heaters, electric resistance pool heaters, and electric heat pump pool heaters is 10 C.F.R. section 430.23(p) (Appendix P to subpart B of part 430).
(2) Test Method for Portable Electric Spas.
(A) The test method for portable electric spas manufactured on or after January 1, 2006, and before June 1, 2019, is as follows:
1. Minimum continuous testing time shall be 72 hours.
2. The spa shall be filled with water to the halfway point between the bottom of the skimmer basket opening and the top of the spa. If there is no skimmer basket, the spa shall be filled with water to six inches below the top of the spa.
3. The water temperature shall be 102oF, ± 2oF for the duration of the test.
4. The ambient air temperature shall be 60oF, ± 3oF for the duration of the test.
5. The standard cover that comes with the unit shall be used during the test.
6. The test shall start when the water temperature has been at 102oF, ± 2oF for at least four hours.
7. Record the total energy use for the period of test, starting at the end of the first heating cycle after the stabilization period specified in section 1604(g)(2)(A)6., of this Article, and finishing at the end of the first heating cycle after 72 hours has elapsed.
8. The unit shall remain covered and in the default operation mode during the test. Energy-conserving circulation functions, if present, must not be enabled if not appropriate for continuous, long-term use. Ancillary equipment including, but not limited to lights, audio systems, and water treatment devices, shall remain connected to the mains but may be turned off during the test if their controls are user accessible.
9. The measured standby power shall be normalized to a temperature difference of 37oF using the equation,
10. Data reported shall include: spa identification (make, model, S/N, specifications); volume of the unit in gallons; supply voltage; minimum, maximum, and average water temperatures during test; minimum, maximum, and average ambient air temperatures during test; date of test; length of test (t, in hours); total energy use during the test (E, in Wh); and normalized standby power (Pnorm, in watts).
(B) The test method for portable electric spas manufactured on or after June 1, 2019, is ANSI/APSP/ICC-14 2014, excluding section 8.2, and with the following modifications:
1. All portable electric spas shall be filled with water to the halfway point between the bottom of the skimmer opening and the top of the skimmer opening. In the absence of a skimmer, the fill volume is six inches below the overflow level of the spa.
2. For standard spas and inflatable spas, the test shall start when the water temperature has been at 1020F, ±2oF for at least four hours. The water temperature of the spa shall be a minimum 1000F for the duration of the test.
3. For exercise spas, the test shall start when the water temperature has been at 870F, ±2oF for at least four hours. The water temperature of the spa shall be a minimum 850F for the duration of the test. If the exercise spa is capable of maintaining a minimum water temperature of 1000F for the duration of the test, the exercise spa shall be tested in accordance with section 1604(g)(2)(B)2.
4. For combination spas, the standard spa portion shall be tested in accordance with section 1604(g)(2)(B)2., and the exercise spa portion shall be tested in accordance with section 1604(g)(2)(B)3. Record the total energy use for each spa portion separately as described in Section 5.6.5 of ANSI/APSP/ICC-14 2014, while both spa portions are powered on for the duration of the test.
(C) Test lab report requirements for portable electric spas manufactured on or after June 1, 2019. In addition to the requirements of section 5 of ANSI/APSP/ICC-14 2014 and section 1606 Table X, test lab reports shall include: date of test; minimum and maximum water temperatures settings; copy of the label(s) per section 1607(d)(14)(B); minimum, maximum, and average water temperatures during test; minimum, maximum, and average ambient air temperatures during test; length of test (in hours); record and plot ambient air temperature (in degrees Fahrenheit), water temperature (in degrees Fahrenheit), current (in amps), and voltage (in volts) at a maximum interval of five minutes during test; and, for inflatable spas, a list of the accessories that were tested with the spa.
(3) Test Method for Residential Pool Pumps
The test method for residential pool pumps is as follows:
(A) Reported motor efficiency shall be verifiable by test method IEEE 114-2001.
(B) ANSI/HI 1.6-2000 shall be used for the measurement of pump efficiency.
(C) Three curves shall be calculated:
Curve A: H = 0.0167 x F2
Curve B: H = 0.050 x F2
Curve C: H = 0.0082 x F2
Where:
H is the total system head in feet of water.
F is the flow rate in gallons per minute (gpm).
(D) For each curve (A, B, or C), the pump head shall be adjusted until the flow and head lie on the curve. The following shall be tested and reported (i) for each curve for single-speed pumps or (ii) for each curve at both highest and lowest speeds for two-, multi-, or variable-speed pumps:
1. Motor nominal speed (RPM)
2. Flow (gallons per minute)
3. Power (watts and volt amps)
4. Energy Factor (gallons per watt hour)
Where the Energy Factor (EF) is calculated as:
EF = Flow (gpm) * 60 / Power (watts)
(4) Test Method for Pumps
The test method for pumps is 10 C.F.R. section 431.464 (Appendix A to subpart Y of part 431).
(h) Plumbing Fittings.
(1) Commercial Pre-Rinse Spray Valves. The test method for commercial pre-rinse spray valves is 10 C.F.R. sections 431.263 and 431.264.
(2) Showerheads. The test methods for showerheads are:
(A) Maximum flow rate test. The test method for determining maximum flow rate of a showerhead is 10 C.F.R. section 430.23(t) (Appendix S to subpart B of part 430).
(B) Minimum flow rate test. The test method for determining minimum flow rates of a showerhead is ASME A112.18.1-2012 / CSA B125.1-2012, Section 5.12.
(C) Showerheads with multiple nozzles. Showerheads with multiple nozzles shall be tested with all nozzles in use at the same time.
(3) Other Plumbing Fittings. The test method for other plumbing fittings is 10 C.F.R. Section 430.23(s) (Appendix S to subpart B of part 430).
(4) Showerhead-tub spout diverter combinations. Showerhead-tub spout diverter combinations shall have both the showerhead and tub spout diverter tested individually.
(5) Tub Spout Diverters. A tub spout diverter manufactured on or after June 1, 2016 shall be tested in accordance with ASME A112.18.1-2012/CSA B125.1-12, Section 5.3.6 for the rate of leakage conducted prior to life cycle testing and Section 5.6.1.5 for the rate of leakage conducted after life cycling testing.
(i) Plumbing Fixtures.
The test methods for plumbing fixtures are:
(1) Water Closets. The test method for testing gallons per flush of water closets is 10 C.F.R. Section 430.23(u) (Appendix T to subpart B of part 430). See section 1604(i)(3) of this Article for the required waste extraction test.
(2) Urinals. The test method for testing gallons per flush of urinals is 10 C.F.R. section 430.23(v) (Appendix T to subpart B of part 430).
(3) Waste Extraction Test for Water Closets. The waste extraction test for water closets is Section 7.10 of ASME A112.19.2/CSA B45.1-2013.
(j) Fluorescent Lamp Ballasts and Deep-Dimming Fluorescent Lamp Ballasts.
(1) Fluorescent Lamp Ballasts Except Deep-Dimming Fluorescent Lamp Ballasts. The test method for fluorescent lamp ballasts is 10 C.F.R. section 430.23(q) (Appendix Q to subpart B of part 430).
(2) Deep-Dimming Fluorescent Lamp Ballasts. Deep-dimming fluorescent lamp ballasts shall be tested using 10 C.F.R. Section 430.23(q) (Appendix Q to subpart B of part 430) (referred to as the “federal test method” in the following subsections), modified as follows:
(A) The control signal to the ballast shall indicate full output. The arc power of all connected lamps shall be measured and then added together. This result will be referred to as “maximum arc power.” An appropriate lighting control shall be selected to achieve the control signal used to determine the maximum arc power and to tune the ballast to the appropriate dimming levels. The controls shall be selected by using the following methodology:
1. If the ballast manufacturer also manufactures a lighting control designed to be operated with the ballast, the test shall be conducted using the ballast manufacturer's lighting control. Or;
2. If the manufacturer does not manufacture a compatible lighting control, but recommends the use of specific manufacturer and/or model of lighting control, such as in its product documentation, the test shall be conducted using a lighting control from the list of manufacturer-recommended lighting controls. Or;
3. If the manufacturer does not manufacture a compatible lighting control, and does not recommend any specific lighting controls, the lab technician shall select a lighting control that sufficiently controls the ballast to complete the test.
4. If multiple control options are available, use the lighting control that is capable of using all of the features of a ballast and with the minimum amount of other features. The lighting control manufacturer and model number shall appear on the test report.
(B) Three sets of input power and arc power shall be measured using the federal test procedure with the total arc power tuned to 100, 80, and 50 percent of the measured maximum arc power. If a step dimming ballast or a ballast that can only turn connected lamps on or off has dimming steps other than 80 and 50 percent, then the closest step that is between 90 and including 65 percent shall be used for 80 percent testing, and the closest step that is between 65 and including 35 percent shall be used for 50 percent testing. If no step exists in the above prescribed ranges, then no result shall be recorded for that percentage dimming test. The resulting input powers shall be recorded and referred to as P100, P80, and P50. The resulting arc powers shall be recorded and referred to as AP100, AP80, and AP50. BLE100 shall be calculated as AP100/P100, BLE80 as AP80/P80, and BLE50 as AP50/P50. The measurement of power factor shall be taken during the measurement of maximum arc power and reported.
(C) Standby mode test: the ballast shall also be tested with a control input set to the lowest dimming state possible up to and including no light output. The input power to the ballast shall be measured and recorded as P0. The measurement must be taken 90 minutes after entering this state. P0 shall be recorded as the mean value of measurements taken at 5-second intervals over a 5-minute period.
(D) The weighted ballast luminous efficacy shall be calculated using the following formula and table:
Weighted ballast luminous efficacy = BLE100 x w100 + BLE80 x w80 + BLE50 x w50
Where the time values (w100, w80, w50) are taken from the appropriate table below:
Table J-1
Percentage Time of Operation Table
(k) Lamps.
(1) The test method for general service incandescent lamps, incandescent reflector lamps, and federally regulated general service fluorescent lamps is 10 C.F.R. section 430.23(r) (Appendix R to subpart B of part 430).
(2) The test method for compact fluorescent lamps is 10 C.F.R. section 430.23(y) (Appendix W to subpart B of part 430).
(3) The test method for integrated LED lamps is 10 C.F.R. section 430.23(ee) (Appendix BB to subpart B of part 430). For certification, compliance, and enforcement purposes, the sampling provisions in 10 C.F.R. section 429.56 shall be used.
(4) The optional test methods for state-regulated small diameter directional lamps and state-regulated LED lamps are shown in Table K-1. Optional test procedures are conditionally required depending on manufacturer claims of performance as described in sections 1607(d)(13) of this Article and 1606 Table X of this Article. For certification, compliance, and enforcement purposes, the sampling provisions in 10 C.F.R. section 429.56 shall be used.
Table K-1
Optional Test Methods for State-Regulated LED Lamps and LED State-Regulated Small Diameter Directional Lamps
Measurement
Test Procedure
Flicker
Title 24, part 6, Joint Appendix 10 (2015),
tested at both 100 percent and 20 percent
output. Lamps with a percent amplitude
modulation (percent flicker) less than 30
percent at frequencies less than 200 Hz shall
report “yes” for “reduced flicker operation”
described in section 1606 of this Article,
otherwise report “no”.
Lumen Maintenance, Rated
Title 24, part 6, Joint Appendix 8 (2015).
Life, and Survival Rate for
Compliance with Title 24 Joint
Appendix 8 and minimum
dimming level
Audible Noise
ENERGY STAR Recommended Practice -
Noise (2013) with the following modification:
measurements shall be taken at 100 percent
output as well as at 20 percent output if
dimmable.
(5) The test method for general service lamps that are other than lamp types described in sections 1604(k)(1) through 1604(k)(3) of this Article is 10 C.F.R. section 430.23(gg) (Appendix DD to Subpart B of part 430).
(l) Emergency Lighting and Self-Contained Lighting Controls.
(1) Emergency Lighting. The test method for illuminated exit signs is 10 C.F.R. section 431.204(b).
(2) Self-Contained Lighting Controls. There is no test method for self-contained lighting controls.
(m) Traffic Signal Modules.
Traffic Signal Modules. The test method for traffic signal modules for vehicle or pedestrian control is 10 C.F.R. section 431.224.
(n) Luminaires and Torchieres.
(1) Torchieres.
There is no test method for torchieres.
(2) Metal Halide Luminaires.
The test method for metal halide luminaires is ANSI C82.6-2005. Ballasts may be tested separately, outside the luminaire. A sample of at least five ballasts shall be tested for each lamp wattage for which the luminaire and ballasts are rated. The average of these tests shall be used for certification and compliance purposes.
Ballasts efficiency for High Intensity Discharge (HID) luminaire means the efficiency of a lamp and ballast combination expressed as a percentage and calculated by Efficiency = Pout/Pin, as measured. Pout is the measured operating lamp wattage and P Pin is the measured operating input wattage.
The lamp, and the capacitor when it is provided, is to constitute a nominal system in accordance with ANSI C78.43-2004. Pin and Pout are to be measured after lamps have been stabilized according to Section 4.4 of ANSI C82.6-2005 using a wattmeter with accuracy specified in Section 4.5 of ANSI C82.6-2005 for ballasts with a frequency of 60 Hz and shall have a basic accuracy of + 0.5 percent at the higher of (a.) three times the output operating frequency of the ballast, or (b.) 2 kHz for ballast with a frequency greater than 60 Hz.
(3) Under-Cabinet Luminaires.
The test method for under-cabinet luminaires is 10 C.F.R. 430.23(q) (Appendix Q to subpart B of part 430 (2015)).
(4) Portable Luminaires.
(A) The test methods for LED luminaires using LED lamps are shown in Table K-1 of section 1604(k)(4) of this Article.
(B) The test methods for LED luminaires using LED light engines are California Joint Appendix JA8 - 2008, “Testing of Light Emitting Diode Light Sources,” or IES LM-79-08, “Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products,” at manufacturer's option.
(o) Dishwashers.
The test method for dishwashers is 10 C.F.R. section 430.23(c) (Appendix C1 to subpart B of part 430).
(p) Clothes Washers.
(1) Clothes Washers That Are Consumer Products. The test method for clothes washers that are consumer products is 10 C.F.R. section 430.23(j) (Appendix J2 to subpart B of part 430).
(2) Commercial Clothes Washers.
(A) Testing Before January 1, 2018. The test method for commercial clothes washers before January 1, 2018 is 10 C.F.R. section 430.23(j) (Appendix J1 to subpart B of part 430).
(B) Testing On or After January 1, 2018. The test method for commercial clothes washers on or after January 1, 2018 is 10 C.F.R. section 430.23(j) (Appendix J2 to subpart B of part 430).
(q) Clothes Dryers.
The test methods for clothes dryers are 10 C.F.R. section 430.23(d) (Appendix D1 or Appendix D2 to subpart B of part 430). Manufacturers must use a single appendix for all representations, including certifications of compliance, and may not use appendix D1 for certain representations and appendix D2 for other representations.
(r) Cooking Products and Food Service Equipment.
The test methods for cooking products that are consumer products, commercial hot food holding cabinets, commercial convection ovens and commercial range tops are shown in Table R-1.
Table R-1
Cooking Product and Food Service Equipment Test Methods
(s) Electric Motors and Compressors.
(1) Electric Motors, Except Small Electric Motors. The test methods for electric motors are 10 C.F.R. sections 431.15, 431.16, 431.17, 431.18, 431.19, 431.20, and 431.21, including but not limited to provisions on testing laboratories, recognition of accreditation bodies, and recognition of certification programs.
(2) Small Electric Motors. The test methods for small electric motors are 10 C.F.R. sections 431.443, 431.444 and 431.445, including but not limited to provisions on alternative efficiency determination method (AEDM) and additional testing requirements concerning selection of models to be tested if an AEDM is to be applied.
(3) Compressors. The test method for state-regulated compressors is 10 C.F.R. section 431.344 (Appendix A to Subpart T of 10 C.F.R., § 431), including but not limited to provisions on alternative efficiency determination method (AEDM) and additional testing requirements concerning selection of models to be tested if an AEDM is to be applied, in 10 C.F.R. section 429.63 and 10 C.F.R. section 429.70.
(t) Distribution Transformers.
The test method for distribution transformers is 10 C.F.R. section 431.193 (Appendix A of subpart K).
(u) External Power Supplies.
(1) The test method for federally regulated direct operation external power supplies and federally regulated indirect operation Class A external power supplies is 10 C.F.R. section 430.23(bb) (Appendix Z to subpart B of part 430).
(2) The test method for state- regulated external power supplies is US EPA Test Method for Calculating the Energy Efficiency of Single-Voltage External AC-DC and AC-AC Power Supplies dated August 11, 2004, except that the test voltage specified in Section 4(d) of the test method shall be only 115 volts, 60 Hz.
(v) Computers, Computer Monitors, Televisions, Signage Displays, and Consumer Audio and Video Equipment.
(1) Consumer Audio and Video Equipment. The test method for standby-passive mode consumer audio and video equipment is International Electrotechnical Commission (IEC) 62087:2002(E) - “Methods of Measurement for the Power Consumption of Audio, Video, and Related Equipment.”
(2) Televisions and Signage Displays. The test method for televisions manufactured on or after April 24, 2014 is 10 C.F.R. section 430.23(h) (Appendix H to subpart B of part 430). The test method for signage displays manufactured on or after April 24, 2014, is 10 C.F.R. Section 430.23(h) (Appendix H to subpart B of part 430) (January 1, 2014).
(3) Computer Monitors. The test method for computer monitors is the ENERGY STAR Program Requirements for Displays, Final Test Method (September 2015), with the following modifications:
(A) On mode measurements shall be made using the IEC 62087: 2011 and computer monitor sleep mode and computer monitor off mode measurements shall be made using the IEC 62301:2011, as specified in the ENERGY STAR Program Requirements for Displays, Final Test Method (September 2015).
(B) A computer monitor shall be tested as required by the test procedure for each of the following:
1. On mode power draw.
2. Computer monitor sleep mode power draw.
3. Computer monitor off mode power draw.
(C) Product features and functions not specifically addressed by the test method shall be turned off or disconnected. Built-in speakers shall be muted or turned down to their lowest volume setting for the on mode power draw test.
(D) Before starting the test procedure for measuring on mode power draw, any feature unrelated to the display of images (for example USB hubs, webcams, speakers, LAN connections, and SD card readers) shall be turned off.
(4) Computers. The test method for computers is the ENERGY STAR Program Requirements for Computers, Final Test Method (Rev. March-2016), with the following modifications:
(A) Settings regarding hard-disk spinning shall not be altered from the default as-shipped settings.
(B) The total annual energy consumption of a computer shall be calculated using Equation 1 in Section 3 of the ENERGY STAR Program Requirements for Computers, Eligibility Criteria Version 6.1 (Rev. March-2016).
1. Computers manufactured before July 1, 2021 shall use the “conventional” mode weighting of Table 3 for a desktop computer, a mobile gaming system, a small-scale server, a high expandability computer, or a thin client, or Table 4 for a notebook computer, a mobile workstation, or a portable all-in-one computer, contained within Section 3 of the ENERGY STAR Program Requirements for Computers, Final Test Method (Rev. March-2016), unless they meet either the criteria in Section 1604(v)(4)(B)2. of this Article to use “full capability” mode weighting, or the criteria in Section 1604(v)(4)(B)3. of this Article to use “remote wake.”
2. In order to use the “full capability” mode weighting a computer shall have the following features enabled as shipped:
a. Maintain Ethernet (IEEE 802.3-2015) or wireless (IEEE 802.11-2012) network addresses and network connection capability while in ACPI System Level S3 Sleep Mode or an alternative to ACPI S3 sleep mode;
b. Resume from ACPI System Level S3 Sleep Mode or an alternative to ACPI S3 sleep mode upon request from outside the local network; and
c. Support advertising host services and network name while in ACPI System Level S3 Sleep Mode or an alternative to ACPI S3 sleep mode.
3. In order to use the “remote wake” mode weighting a computer shall have the following features enabled as shipped:
a. Maintain Ethernet (IEEE 802.3-2015) or wireless (IEEE 802.11-2012) network addresses and network connection capability while in ACPI System Level S3 Sleep Mode or an alternative to ACPI S3 sleep mode; and
b. Resume from ACPI System Level S3 Sleep Mode or an alternative to ACPI S3 sleep mode upon request from outside the local network.
4. Computers manufactured on or after July 1, 2021, shall use the “conventional” mode weighting of Table 3 for a desktop computer, a mobile gaming system, a small-scale server, a high-expandability computer, or a thin client, or Table 4 for a notebook computer, a mobile workstation, or a portable all-in-one computer, contained within Section 3 of the ENERGY STAR Program Requirements for Computers, Eligibility Criteria Version 6.1 (Rev. March-2016).
5. Workstations shall calculate total annual energy consumption using the weighting of Table 8, contained within Section 3 of the ENERGY STAR Program Requirements for Computers, Eligibility Criteria Version 6.1 (Rev. March-2016).
(C) The expandability score calculation shall be included in test reports and shall be calculated as follows:
1. Identify the score for each individual interface type as determined by Table V-1 and then multiply by the total number of occurrences of that particular interface type present in the system as sold or offered for sale. Finally, sum the subtotals for all interface types.
2. Each instance of an interface may only receive one score.
3. Add 100 to the score.
Table V-1
Interface Types and Scores for Expandability Score Calculation
(D) A computer monitor used in the testing of desktop computers shall have a native resolution of at least 1920x1080 pixels and use progressive scanning. The computer operating system shall be set to operate at a minimum of 1920x1080 pixels and progressive scanning. If multiple display connections are available on the computer, choose the correct connection using the following criteria:
1. If hybrid graphics is available, choose the port that enables hybrid graphics.
2. If a discrete GPU is installed, choose a connection to the first GPU, except for where it conflicts with subdivision (D)(1) of this section.
3. If no discrete GPU is installed, choose a connection to a port integrated into the motherboard.
4. If there are multiple connector ports to choose from pursuant to subdivisions (v)(5)(D)1. through (v)(5)(D)3. of this section, connect the display to a port using the first available from the port types listed below:
a. Display Port
b. HDMI
c. DVI
d. VGA
e. Other
(E) An integrated desktop computer, mobile gaming system, or notebook computer shall be tested using the integrated display's native resolution.
(F) High expandability computers shall be configured for the test in a manner identical to desktop computers. Mobile gaming systems and mobile workstations shall be configured for the test in a manner identical to notebook computers.
(G) For purposes of providing data as required in section 1606 of this Article, desktop computers, thin clients, mobile gaming systems, notebook computers, and portable all-in-ones shall be tested by selecting the configuration that has the greatest allowable energy consumption as provided for in section 1605.3(v)(5) of this Article. If multiple configurations exist that meet this criteria, select the configuration that will yield the greatest annual energy consumption as measured by the test procedure.
(H) The computer sleep mode power measurement shall be tested in a modified manner from the test procedure described in IEC 62623:2012. Instead of measuring power after manually entering sleep mode, the power measurement shall begin no sooner than 30 minutes and no later than 31 minutes of user inactivity on the unit under test. This measurement shall be performed after the long-idle test without altering the unit under test.
(I) The power factor of a computer power supply and compliance with Table V-9 in Section 1605.3(v)(6) of this Article shall both be determined by the following test procedure: Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.7 (March 1, 2014). In addition the median power factor during short-idle measurements shall be recorded in the test report.
(w) Battery Chargers and Battery Charger Systems.
(1) Test Method for Federally Regulated Battery Chargers and Federally Regulated Uninterruptible Power Supplies. The test method for federally regulated battery chargers and federally regulated uninterruptible power supplies is 10 C.F.R. section 430.23(aa) (Appendix Y to subpart B of part 430).
(2) Test Method for Small Battery Charger Systems. The test method for small battery charger systems that are not federally regulated battery chargers, federally regulated uninterruptible power supplies, battery backups, or non-federally regulated uninterruptible power supplies is 10 C.F.R. section 430.23(aa) (Appendix Y to subpart B of part 430) (Jan. 1, 2017).
(A) Multi-port battery charger systems shall be tested for 24-hour efficiency and maintenance mode with a battery in each port.
(B) For single port small battery charger systems, the highest 24-hour charge and maintenance energy, maintenance mode, and no battery mode results of the test procedure shall be used for purposes of reporting and determining compliance with section 1605.3(w)(2), Table W-3 of this Article.
(C) For purposes of computing the small battery charger system standard, the number of ports included in a multi-port charger system shall be equal to the number ports that are separately controlled. For example a multi-port charger system that charges eight batteries by using two charge controllers that charge four batteries in parallel would use two for “N” as described in section 1605.3(w)(2),Table W-3 of this Article.
(D) Small battery charger systems that are not consumer products may use the battery manufacturer's recommended end of discharge voltage in place of values in 10 CFR section 420.23(aa) (Appendix Y to subpart B of part 430) (Jan. 1, 2017), Table 3.3.2, where the table's values are not applicable.
(3) Test Method for Battery Backups and Non-Federally Regulated Uninterruptible Power Supplies. The test method for battery backups and non-federally regulated uninterruptible power supplies is 10 C.F.R. section 430.23(aa) (Appendix Y to subpart B of part 430) (Jan. 1, 2016).
(4) Test Method for Large Battery Charger Systems. The test method for large battery charger systems that are not federally regulated battery chargers or federally regulated uninterruptible power supplies is Energy Efficiency Battery Charger System Test Procedure Version 2.2 dated November 12, 2008 and published by ECOS and EPRI Solutions with the following modifications:
(A) The test procedure shall be conducted for 100, 80, and 40 percent discharge rates for only one charge profile, battery capacity, and battery voltage. The manufacturer shall test one battery and one charge profile using the following criteria:
1. the charge profile with the largest charge return factor;
2. the smallest rated battery capacity; and
3. the lowest voltage battery available at that rated capacity.
(B) The battery manufacturer's recommended end of discharge voltage may be used in place of values in the test method part 1, section III.F, Table D where the table's values are not applicable.
(x) Landscape Irrigation Equipment.
(1) Spray Sprinkler Bodies.
(A) The test method for a spray sprinkler body is Appendix B of the WaterSense® Specification for Spray Sprinkler Bodies Version 1.0, September 21, 2017. For certification, compliance, and enforcement purposes, the sampling provisions in Appendix B of the WaterSense® Specification for Spray Sprinkler Bodies Version 1.0, September 21, 2017 shall be used.
The following documents are incorporated by reference in section 1604.
CALIFORNIA ENERGY COMMISSION TEST METHODS
CEC/Gas-Fired Heat Pumps
Efficiency Calculation Method for Gas-
Exceptional Method (1996)
Fired Heat Pumps as a New Compliance
Option (1996)
California Title 24, part 6, Joint
Qualification Requirements for High
Appendix 8 JA-8 - 2015
Efficacy Light Sources
California Title 24, part 6, Joint
Test Method for Measuring Flicker of
Appendix 10 JA-10 - 2015
Lighting Systems and Reporting
Requirements
California Joint Appendix
Testing of Light Emitting Diode Light
JA8 - 2008
Sources
Copies available from:
CALIFORNIA ENERGY COMMISSION
ENERGY HOTLINE
1516 NINTH STREET, MS-25
SACRAMENTO, CALIFORNIA 95814
PHONE: (916) 654-5106
FAX: (916) 654-4304
FEDERAL TEST METHODS
C.F.R., Title 10, section 429.56, 429.63, and 429.70
C.F.R., Title 10, section 430.23, and 10 C.F.R. Appendixes A, B, C1, D1, D2, E, F, H, I, J1, J2, M, N, O, P, Q, R, S, T, U, V, W, X, S1, Y, Z, AA, BB, CC, and DD of subpart B of part 430
C.F.R., Title 10, sections 431.15, 431.16, 431.17, 431.18, 431.19, 431.20, and 431.21
C.F.R., Title 10, sections 431.63 and 431.64
C.F.R., Title 10, sections 431.75 and 431.76
C.F.R., Title 10, sections 431.85 and 431.86
C.F.R., Title 10, sections 431.95 and 431.96
C.F.R., Title 10, sections 431.105 and 431.106
C.F.R., Title 10, sections 431.133 and 431.134
C.F.R., Title 10, section 431.193
C.F.R., Title 10, section 431.204(b)
C.F.R., Title 10, section 431.224
C.F.R., Title 10, sections 431.263 and 431.264
C.F.R., Title 10, sections 431.293 and 431.294
C.F.R., Title 10, sections 431.303 and 431.304
C.F.R., Title 10, section 431.344, Appendix A to Subpart T of 10 C.F.R., § 431
C.F.R., Title 10, sections 431.443, 431.444, and 431.445
C.F.R., Title 10, section 431.464
C.F.R., Title 10, section 431 subpart G
Copies available from:
Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402
www.ecfr.gov
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA)
ENERGY STAR® Program Requirements for
Bottled Water Coolers (2004)
ENERGY STAR® Program Requirements for
Computers, subparts Eligibility Criteria
Version 6.1 (Rev. March-2016) and Final
Test Method (Rev. March-2016)
ENERGY STAR® Program Requirements for
Displays, subpart Final Test Method
(Rev. Sep-2015)
EPA “Test Method for Calculating the Energy
Efficiency of Single-Voltage External
AC-DC and AC-AC Power Supplies”
August 11, 2004)
Energy Star Guidelines, “Measuring Interior Volume”
(Test for measuring interior volume of commercial
hot food holding cabinets)
ENERGY STAR Recommended
EPA ENERGY STAR® Program
Practice - Noise (2013)
Requirements Product Specification
for Lamps (Light Bulbs)
Version 1.1 (August 2014).
Copies available from:
US EPA
Climate Protection Partnership
ENERGY STAR Programs Hotline &
Distribution
(MS-6202J)
1200 Pennsylvania Ave NW
Washington, DC 20460
www.energystar.gov
Appendix B of the WaterSense®
Specification for
Spray Sprinkler Bodies
Version 1.0 (Dated September 21, 2017)
Copies available from:
WaterSense®
U.S. Environmental Protection Agency
Office of Wastewater Management
(4204M)
1200 Pennsylvania Avenue, N.W.
Washington, D.C. 20460
https://www.epa.gov/watersense
AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI)
AHRI 680-2009
2009 Standard for Performance Rating of
Residential Air Filter Equipment
Copies available from:
Air-Conditioning, Heating, and
Refrigeration Institute (AHRI)
2111 Wilson Blvd, Suite 500
Arlington, VA 22201
Phone: (703) 524-8800
FAX: (703) 562-1942
http://www.ahrinet.org/
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI C78.43-2004
American National Standards for Electric
Lamps - Single-Ended Metal Halide Lamps
ANSI C82.6-2005
Ballasts for High Intensity Discharge Lamps
- Method of Measurement
ANSI Z21.10.3-1998
Standard for Gas Water Heaters, Volume III,
Storage Water Heaters with Input Ratings
Above 75,000 Btu per hour, Circulating and
Instantaneous
ANSI Z21.40.4-1996
Performance Testing and Rating of
Gas-Fired Air-Conditioning and Heat Pump
Appliances
ANSI Z83.8-2002
Standard for Gas Unit Heaters and Gas-Fired
Duct Furnaces
ANSI Z83.19-2001
Standard for Gas-Fired High-Intensity
Infrared Heaters
ANSI Z83.20-2001
Standard for Gas-Fired Low-Intensity
Infrared Heaters
ANSI/AHRI 550-590(I-P)2011
Performance Rating of Water-Chilling and
Heat Pump Water-Heating Packages Using
the Vapor Compression Cycle
Copies available from:
American National Standards Institute
1819 L Street, NW, 6th Floor
Washington DC 20036
www.ansi.org
Phone: (202) 293-8020
FAX: (202) 293-9287
AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME)
ASME A112.19.2/CSA B45.1-2013
Ceramic Plumbing Fixtures
ASME A112.18.1-2012/CSA B125.1-2012
Plumbing Supply Fittings
Copies available from:
ASME HEADQUARTERS
TWO PARK AVENUE
NEW YORK, NY 10016-5990
WWW.ASME.ORG
PHONE: 800-843-2763 (U.S/CANADA)
001-800-843-2763 (MEXICO)
973-882-1170 (OUTSIDE NORTH AMERICA)
EMAIL: CUSTOMERCARE@ASME.ORG
AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)
ANSI/ASTM F1496-99
Standard Test Method for Performance of
Convection Ovens
ANSI/ASTM F1521-96
Standard Test Methods for Performance of
Range Tops
ANSI/ASTM F2140-01
Standard Test Method for the Performance of
Hot Food Holding Cabinets
ANSI/ASTM F2143-01
Standard Test Method for the Performance of
Refrigerated Buffet and Preparation Tables
ASTM F2644-07
Standard Test Method for Performance of
Commercial Patio Heaters
Copies available from:
ASTM
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
www.astm.org
Phone: (610) 832-9585
FAX: (610) 832-9555
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)
ASHRAE 52.2-2012
Method of Testing General Ventilation
Air-Cleaning Devices for Removal
Efficiency by Particle Size
ANSI/ASHRAE 118.2-1993
Method of Testing for Rating Residential
Water Heaters
ANSI/ASHRAE 124-2007
Method of Testing for Rating Combination
Space-Heating and Water-Heating
Appliances
ANSI/ASHRAE 127-2001
Method of Testing for Rating Computer and
Data Processing Room Unitary
Air-Conditioners
ANSI/ASHRAE 128-2001
Method of Rating Spot Unitary Air
Conditioners
ANSI/ASHRAE 133-2008
Method of Testing Direct Evaporative
Air Coolers
ANSI/ASHRAE 143-2007
Method of Test for Rating Indirect
Evaporative Coolers
ANSI/ASHRAE 146-1998
Method of Testing and Rating Pool Heaters
Copies available from:
American Society of Heating,
Refrigerating and Air-Conditioning
Engineers
1791 Tullie Circle N.E.
Atlanta, GA 30329
www.ashrae.org
Phone: (800) 527-4723 (U.S./Canada) or
(404) 636-8400
FAX: (404) 321-5478
THE ASSOCIATION OF POOL AND SPA PROFESSIONALS (APSP)
ANSI/APSP/ICC-14 2014
American National Standard for Portable
Electric Spa Energy Efficiency
Copies available from:
The Association of Pool and Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria, VA 22314-4695
www.apsp.org
Phone: (703) 838-0083
CANADIAN STANDARDS ASSOCIATION (CSA)
CSA B45.1-2013
Ceramic Plumbing Fixtures
Copies available from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, Ontario, Canada, M9W 1R3
Phone: (416) 747-4044
http:/shop.csa.ca/
ECOS CONSULTING
Energy Efficiency Battery Charger System
Test Procedure Version 2.2 dated November
12, 2008
Copies available from:
Ecos Consulting
801 Florida Road, # 11
Durango, CO 81301
http://www.efficientproducts.org/
Phone: (970) 259-6801
FAX: (970) 259-8585
ECOVA
Generalized Test Protocol for Calculating the
Energy Efficiency of Internal Ac-Dc and
Dc-Dc Power Supplies Revision 6.7
(March 1, 2014)
Copies available from:
PLUG LOAD SOLUTIONS BY ECOVA
www.plugloadsolutions.com
Phone: (971) 201-4180
HOME VENTILATING INSTITUTE (HVI)
HVI-Publication 916
29 September 2015 HVI
Air-flow Test Procedure
Copies available from:
Home Ventilating Institute
1000 N. Rand Rd., Suite 214
Wauconda, IL 60084
www.hvi.org
Phone: (847) 526-2010
FAX: (847) 526-3993
HYDRAULIC INSTITUTE (HI)
ANSI/HI 1.6-2000
Centrifugal Pump Tests
Copies available from:
Hydraulic Institute
6 Campus Dr., First Floor North
Parsippany, NJ 07054-4405
http://www.pumps.org/
www.hydraulicinstitute.com
Phone: (973) 267-9700
Fax: (973) 267-9055
ILLUMINATING ENGINGEERING SOCIETY (IES)
IES LM-79-08
Approved Method: Electrical and
Photometric Measurements of Solid-State
Lighting Products
IES LM-84-14
Measuring Luminous Flux and Color
Maintenance of LED Lamps, Light
Engines, and Luminaires
IES TM-28 (2014)
Projecting Long-Term Luminous
Flux Maintenance of LED Lamps and
Luminaires
Copies available from:
Illuminating Engineering Society
120 Wall Street, 17th Floor
New York, NY 10005-4001
www.ies.org
Phone: (212) 248-5000
FAX: (212) 248-5017/18
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)
IEC 62087 (2002)(E)
Methods of Measurement for the Power
Consumption of Audio, Video, and Related
Equipment.
IEC 62087:2008(E), Edition 2.0
Methods of Measurement for the Power
Consumption of Audio, Video, and
Related Equipment
IEC 62087: 2011
Methods of measurement for the power
consumption of audio, video and related
equipment
IEC 62301:2011
Household electrical appliances -
Measurement of standby power
IEC 62623:2012
Desktop and notebook computers -
Measurement of energy consumption
Copies available from:
IEC Central Office
3, Rue de Varembé
P.O. Box 131
CH - 1211 Geneva 20
Switzerland
Phone: +41 22 919 02 11
INTERNATIONAL ORGANIZATION FOR STANDARDS (ISO)
ISO 13256-1-1998
Water-source heat pumps-Testing and rating
for performance-part 1: Water-to-air and
brine-to-air heat pumps
Copies available from:
ISO Central Secretariat
International organization for
Standardization (ISO)
1, Rue de Varembé, Case Postale 56
CH-1211 Geneva 20, switzerland
www.iso.org
Phone: +41 22 749 01 11
Fax: +41 22 733 34 30
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
IEEE 114-2001 (Corrected)
Standard Test Procedures for Single-Phase
Induction Motors
IEEE 802.3-2015
IEEE Standard for Ethernet
IEEE 802.11-2012
IEEE Standard for Information technology -
Telecommunications and information
exchange between systems
Local and metropolitan area networks -
Specific requirements
Part 11: Wireless LAN Medium Access
Control (MAC) and Physical Layer (PHY)
Specifications
Copies available from:
Institute of Electrical and Electronics
Engineers
Publications Office
10662 Los Vaqueros Circle
PO Box 3014
Los Alamitos, CA 90720-1264
www.ieee.org
Phone: (714) 821-8380
Fax: (714) 821-4010
UNIFIED EXTENSIBLE FIRMWARE INTERFACE FORUM
Advanced Configuration and
Advanced Configuration and
Power Interface Specification
Power Interface Specification
Revision 5.0 (December 6, 2011)
and Advanced Configuration and
Power Interface Specification
Revision 5.0 Errata A
(November 13, 2013)
Copies available from:
UEFI FORUM ADMINISTRATION
3855 SW 153RD DRIVE
BEAVERTON, OR 97003 USA
www.uefi.org
Phone: +1 503-619-0864
Fax: +1 503-644-6708
Note: Authority cited: Sections 25213, 25218(e), 25401.9, 25402(a)-25402(c) and 25960, Public Resources Code; and Sections 16, 26 and 30, Governor's Exec. Order No. B-29-15 (April 1, 2015). Reference: Sections 25216.5(d), 25401.9, 25402(a)-25402(c) and 25960, Public Resources Code; and Section 16, Governor's Exec. Order No. B-29-15 (April 1, 2015).
HISTORY
1. Amendment filed 7-21-82; effective thirtieth day thereafter (Register 82, No. 30). For prior history, see Register 80, No. 23.
2. New subsection (g) filed 10-1-82; designated effective 6-2-83 (Register 82, No. 40).
3. Amendment of Table C-2 filed 1-3-83; effective thirtieth day thereafter (Register 83, No. 2).
4. Amendment of subsection (f) filed 1-14-83; effective thirtieth day thereafter (Register 83, No. 3).
5. Amendment of subsection (d)(2) filed 1-20-83; effective thirtieth day thereafter (Register 83, No. 7).
6. Editorial correction of subsections (a) and (b) and Tables A and B (Register 83, No. 18).
7. Amendment of subsection (a) filed 3-26-85; effective thirtieth day thereafter (Register 85, No. 13).
8. Amendment of subsection (c) filed 4-10-85; effective thirtieth day thereafter (Register 85, No. 18).
9. Amendment filed 5-22-85; effective thirtieth day thereafter (Register 85, No. 21).
10. Amendment of subsection (c) filed 4-10-85; effective thirtieth day thereafter (Register 85, No. 21).
11. Amendment filed 7-20-87; operative 8-19-87 (Register 85, No. 30).
12. Amendment filed 8-29-88; operative 9-28-88 (Register 88, No. 37).
13. Amendment of subsections (a)-(c), new subsection (d) reserved, and renumbering and amendment of former subsections (d)-(g) to subsections (e)-(h) filed 6-5-90; operative 7-5-90 (Register 90, No. 31).
14. Amendment filed 11-6-91; operative 12-6-91 (Register 92, No. 9).
15. Amendment of Table F-2 filed 1-16-92; operative 1-16-92 pursuant to Government Code section 11346.2 (d) (Register 92, No. 15).
16. Amendment of subsection (f)(2) and Table F-2, new Table F-3, amendment of subsection (f)(3), renumbering and amendment of Table F-3 to Table F-4, and amendment of subsection (f)(4) and renumbering of Table F-4 to F-5 filed 7-23-92; operative 8-24-92 (Register 92, No. 35).
17. Repealer and new section filed 10-28-2002; operative 11-27-2002 (Register 2002, No. 44).
18. Amendment of subsection (f)(5)(E) filed 4-1-2003 as an emergency; operative 4-1-2003 (Register 2003, No. 14). A Certificate of Compliance must be transmitted to OAL by 7-30-2003 or emergency language will be repealed by operation of law on the following day.
19. Certificate of Compliance as to 4-1-2003 order transmitted to OAL 7-8-2003 and filed 8-19-2003 (Register 2003, No. 34).
20. Amendment of subsection (p) and list of incorporated documents filed 7-29-2004; operative 8-28-2004 (Register 2004, No. 31).
21. Amendment filed 3-16-2005; operative 4-15-2005 (Register 2005, No. 11).
22. Amendment of Table A-1, subsection (a)(4), Tables B-1, D, E-1 and F-1, subsections (h)(1), (j)-(k), (n)(3) and (o), Table P-1, subsection (q), Table R, subsections (s) and (u)(1) and federal test methods filed 12-30-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).
23. Amendment of subsection (u)(1) and Note filed 6-22-2006; operative 6-22-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 25).
24. Amendment of Table D and subsections (f)(5)(F), (k) and (n)(2) and amendment of list of incorporated documents filed 12-14-2006; operative 12-14-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 50).
25. Amendment of subsection (c) - Table C-1, subsection (s) and list of incorporated documents filed 8-22-2007; operative 9-17-2007 pursuant to Government Code section 11343.4 (Register 2007, No. 34).
26. Amendment filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
27. Redesignation and amendment of former subsection (k) as new subsection (k)(1), new subsections (k)(2)-(3) and (n)(4) and amendment of list of incorporated standards and Note filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
28. Amendment of subsection (v), including redesignation and amendment of portion of former subsection (v) as new subsection (v)(1), new subsections (v)(2)-(v)(3)(D)6. and amendment of list of incorporated standards filed 9-1-2010; operative 1-1-2011 (Register 2010, No. 36).
29. Amendment of subsection (l), new subsections (l)(1)-(2), amendment of subsections (w)(1) and (w)(2), new subsections (w)(1)(A)-(D) and (w)(2)(A)-(B) and amendment of list of incorporated documents to update revision date of 10 CFR 430.23 filed 10-26-2012; operative 1-1-2013 (Register 2012, No. 43).
30. Amendment filed 4-22-2014; operative 7-1-2014 (Register 2014, No. 17).
31. Amendment of subsection (i), new subsections (i)(1)-(2), amendment of list of incorporated documents and amendment of Note filed with the Secretary of State by the Office of Administrative Law on 5-15-2015. Submitted to OAL for printing only pursuant to Governor's Executive Order No. B-29-15 (4-1-2015); operative 5-15-2015 (Register 2015, No. 20).
32. New subsections (h)(2)-(h)(2)(C), subsection renumbering, amendment of subsection (i)(1), new subsection (i)(2), subsection renumbering and amendment of list of incorporated documents filed 8-20-2015; operative 8-20-2015 pursuant to Governor's Executive Order No. B-29-15, directive 30 (4-1-2015) (Register 2015, No. 34).
33. New subsections (h)(5)-(6) and amendment of subsection (i)(3) filed 2-10-2016; operative 2-10-2016. Exempt from OAL review pursuant to Governor's Executive Order B-29-15, issued 4-1-2015 (Register 2016, No. 7).
34. Amendment of subsections (a) and (c), new subsections (c)(4)-(5), amendment of subsections (d), (f)(1) and (j), new subsections (j)(3)-(j)(3)(D) and amendment of subsections (o), (p) and (w)(2)(B) filed 6-30-2016; operative 7-1-2016 pursuant to Government Code section 11343.4(b)(3) (Register 2016, No. 27).
35. Amendment of subsections (k)(2) and (k)(4), including new table K-1, and list of documents incorporated by reference filed 11-1-2016; operative 1-1-2017 (Register 2016, No. 45).
36. Amendment of subsections (v) and (v)(2)-(3), new subsections (v)(4)-(v)(5)(I) and amendment of list of incorporated documents filed 8-22-2017; operative 10-1-2017 (Register 2017, No. 34).
37. Change without regulatory effect amending Table D-1 and list of incorporated documents filed 9-11-2017 pursuant to section 100, title 1, California Code of Regulations (Register 2017, No. 37).
38. Adoption and amendment of subsections within subsection (g)(2) and amendment of list of incorporated documents filed 7-19-2018; operative 10-1-2019 (Register 2018, No. 29).
39. Amendment filed 9-26-2018; operative 10-1-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 39).
40. Editorial correction of subsection (a)(4) (Register 2018, No. 45).
41. Change without regulatory effect amending footnote to Table K-1, amending Table R-1 and amending list of documents incorporated by reference filed 3-18-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 12).
42. Amendment of subsection (s)(3) and list of documents incorporated by reference filed 6-10-2019; operative 6-10-2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 24).
43. New subsections (x)-(x)(1)(A), amendment of list of documents incorporated by reference and amendment of Note filed 10-7-2019; operative 10-1-2020 pursuant to Government Code section 11343.4(b)(2) and Public Resources Code section 25402(c)(1) (Register 2019, No. 41).
44. Amendment of subsection (k)(1), repealer of subsection (k)(2), subsection renumbering, amendment of newly designated subsections (k)(2)-(3), new subsection (k)(4), amendment of Table K-1 and subsection (k)(5) and amendment of list of documents incorporated by reference filed 12-24-2019; operative 1-1-2020 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 52).
This database is current through 9/11/20 Register 2020, No. 37
20 CCR § 1604, 20 CA ADC § 1604
End of Document© 2020 Thomson Reuters. No claim to original U.S. Government Works.