§ 66264.303. Monitoring and Inspection.
22 CA ADC § 66264.303Barclays Official California Code of Regulations
22 CCR § 66264.303
§ 66264.303. Monitoring and Inspection.
(a) During construction or installation, liners (except in the case of existing portions of landfills exempt from 66264.301(a)) and cover systems (e.g., membranes, sheets, or coatings) shall be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation:
(2) After the final cover is installed, the amount of liquids removed from each leak detection system sump shall be recorded at least monthly. If the liquid level in the sump stays below the pump operating level for two consecutive months, the amount of liquids in the sumps shall be recorded at least quarterly. If the liquid level in the sump stays below the pump operating level for two consecutive quarters, the amount of liquids in the sumps shall be recorded at least semi-annually. If at any time during the post-closure care period the pump operating level is exceeded at units on quarterly or semi-annual recording schedules, the owner or operator shall return to monthly recording of amounts of liquids removed from each sump until the liquid level again stays below the pump operating level for two consecutive months.
Credits
Note: Authority cited: Sections 25150 and 25159, Health and Safety Code; and Governor's Reorganization Plan Number 1 of 1991. Reference: Sections 25150, 25159 and 25159.5, Health and Safety Code; and 40 CFR Section 264.303.
History
1. New section filed 5-24-91; operative 7-1-91 (Register 91, No. 22).
2. New subsections (c)(1)-(3) and amendment of Note filed 7-19-95; operative 8-18-95 (Register 95, No. 29).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 22, § 66264.303, 22 CA ADC § 66264.303
End of Document |