The following table designates the Energy Saving Measure (ESM) List for the Program and the corresponding requirements for each measure. In any situation in which the Title 20 of the California Code of Regulations, Title 24 of the California Code of Regulations, or any other legal requirement exceeds the requirement specified in the table, the ESM must be installed to meet the legal requirement(s). Where a measure is removed from the ESM list or its requirements are revised, that measure and requirements will continue to be eligible for inclusion in an Eligible Financing Agreement that is submitted to the Program for enrollment within 365 calendar days of the removal or revision of the ESM.
Measure Category
Measure
Requirements
IOU Fuel Source Eligibility
Eligible for Self-Install
Agriculture
Automatic Pump Shut-off Sensor
Electric
Yes
Agriculture
Dehumidification System using Solid or Liquid Desiccant
Electric
No
Agriculture
Dehumidification System with On-site Heat Recovery
Electric
No
Agriculture
Greenhouse Energy Curtain
Electric Gas
Yes
Agriculture
Heat Recovery
Electric Gas
Yes
Agriculture
High Efficiency Booster or Well Pump
Electric
Yes
Agriculture
High Efficiency Irrigation Pump
Electric
Yes
Agriculture
High Efficiency Ventilation Fan
Electric
Yes
Agriculture
Irrigation Pump Performance Testing and Optimization
Electric
No
Agriculture
Plate Cooler
Electric
Yes
Agriculture
Sprinkler-to-Drip Irrigation
Electric
Yes
Agriculture
VFD on Booster or Well Pump Motor
Electric
Yes
Agriculture
VFD on Pump or Fan Motor
Electric
Yes
Appliances
Air Cleaner/Purifier
Energy Star
Electric
Yes
Appliances
Convection Electric Oven
Electric
Yes
Appliances
Convection Gas Oven
Gas
No
Appliances
Induction Range or Cooktop
Electric
Yes
Appliances
Range Hood
Energy Star
Electric
No
Appliances
Residential In-Unit Clothes Dryer (Electric)
Energy Star
Electric
Yes
Appliances
Residential In-Unit Clothes Dryer (Gas)
Energy Star
Gas
No
Appliances
Residential In-Unit Clothes Washer
Energy Star
Electric Gas
Yes
Appliances
Residential In-Unit Dishwasher
Energy Star
Electric Gas
Yes
Appliances
Residential In-Unit Freezer
Energy Star
Electric
Yes
Appliances
Residential In-Unit Refrigerator
Energy Star
Electric
Yes
Building Envelope
Air Sealing
Electric Gas
No
Building Envelope
Attic Insulation
Electric Gas
No
Building Envelope
Cool Roof
Electric
No
Building Envelope
Floor Insulation
Electric Gas
No
Building Envelope
Heat Reflective Coating
Product must have solar reflectance ≥ 0.5 as tested to ASTM C1549-16
Electric
No
Building Envelope
Radiant Barrier
Electric Gas
No
Building Envelope
Wall Insulation
Electric Gas
No
Building Envelope
Window Film
Electric Gas
Yes
Building Envelope
Windows/Glass Doors
Electric Gas
No
Data Centers
Airflow Management Device
Electric
No
Data Centers
Aisle Containment
Electric
Yes
Data Centers
Aisle Layout Optimization
Separate hot and cold aisles
Electric
Yes
Data Centers
Efficient Network Equipment
Energy Star
Electric
Yes
Data Centers
Efficient Server
Energy Star
Electric
Yes
Data Centers
Efficient UPS
Energy Star
Electric
Yes
Data Centers
Server Consolidation
Electric
Yes
Data Centers
Server Virtualization
Electric
Yes
Demand Response
Automated Demand Response Equipment (Electric)
Electric
No
Demand Response
Automated Demand Response Equipment (Gas)
Gas
No
Demand Response
Mechanical Energy Storage (MES) System
Must be used for the purpose of permanent load shifting (PLS)
Electric
No
Demand Response
Thermal Energy Storage (TES) System
Must be used for the purpose of permanent load shifting (PLS)
Electric
No
Food Service
Commercial Cooking Equipment (Electric)
Energy Star electric griddles, ovens, steam cookers, or fryers
Electric
Yes
Food Service
Commercial Cooking Equipment (Gas)
Energy Star gas griddles, ovens, steam cookers, or fryers
Gas
No
Food Service
Commercial Dishwashing Equipment (Electric Hot Water)
Energy Star
Electric
No
Food Service
Commercial Dishwashing Equipment (Gas Hot Water)
Gas
No
Food Service
Hot Holding Cabinet
Energy Star
Electric
Yes
Food Service
Low Flow Pre-Rinse Spray Valve (Electric Hot Water)
Electric
Yes
Food Service
Low Flow Pre-Rinse Spray Valve (Gas Hot Water)
Gas
Yes
Food Service
On-demand Hand Wrap Machine
Electric
Yes
Food Service
Ventilation Hood Control
Electric Gas
No
HVAC
Air Filter Alarm or Sensor
Electric Gas
No
HVAC
Air Filter Upgrade - HEPA
HEPA filter upgrade. Must be installed with an ECM fan motor and a filter sensor or alarm.
Electric Gas
No
HVAC
Air Filter Upgrade - MERV
MERV 13-16 air filter upgrade. Must be installed with an ECM fan motor and a filter sensor or alarm.
Electric Gas
No
HVAC
Air-Side or Water-Side Economizer
Electric
No
HVAC
Air-Source or Ground-Source Heat Pump
Electric
No
HVAC
Automatic Filter Replacement
Electric
Yes
HVAC
Automatic Temperature Setpoint Control
Electric
No
HVAC
Chilled Water Outdoor Temperature Reset
Electric
No
HVAC
Chiller Optimization Control
Electric
No
HVAC
Chiller Upgrade, Retrofit, or Replacement
Electric
No
HVAC
Cold Water Booster Pump
Variable speed pump with ECM motor
Electric
No
HVAC
Compressor or Condenser
Electric
No
HVAC
Condensate Recovery
Gas
No
HVAC
Cooling Tower Upgrade, Retrofit, or Replacement
Electric
No
HVAC
Dedicated Outside Air System (DOAS)
Electric Gas
No
HVAC
Demand Controlled Ventilation
Electric Gas
No
HVAC
Diagnostic or Fault Detection Alert Systems
Electric Gas
No
HVAC
Dual Enthalpy Control
Electric
No
HVAC
Duct Insulation
Electric Gas
Yes
HVAC
Duct Sealing
Electric Gas
No
HVAC
Duct Sizing or Optimization
Electric Gas
No
HVAC
ECM Furnace Fan Motor
Electric
No
HVAC
Evaporative Cooling
Electric
No
HVAC
Fan or Motor Control
Electric
No
HVAC
Furnace - Commercial
Gas
No
HVAC
Furnace - Residential In-Unit
Gas
No
HVAC
Gas Boiler - Residential In-Unit
Gas
No
HVAC
Gas Hydronic Boiler - Commercial
Gas
No
HVAC
Gas Steam Boiler - Commercial
Gas
No
HVAC
Heat Recovery
Electric Gas
No
HVAC
Heat/Energy Recovery Ventilator
Electric Gas
No
HVAC
High Efficiency HVAC Fan
Electric
No
HVAC
High Efficiency HVAC Pump
Electric
No
HVAC
High Performance Circulator Pump
Variable speed pump with ECM motor
Electric
No
HVAC
Hotel Guest Room Occupancy Temperature Control
Electric Gas
Yes
HVAC
HVAC Pipe Insulation
Electric Gas
Yes
HVAC
HVAC Tune-up and Optimization
Electric Gas
No
HVAC
Infrared Heater (Electric)
Electric
No
HVAC
Infrared Heater (Gas)
Gas
No
HVAC
Notched or Synchronous Drive Belt
Electric
Yes
HVAC
Outside Air Reduction
Electric Gas
No
HVAC
Packaged Terminal Air Conditioner (PTAC)
Electric
No
HVAC
Radiative Cooling
Electric
No
HVAC
Residential In-Unit Wall Furnace
Gas
No
HVAC
Rooftop Unit Control
Must include VFD control of RTU supply fan speed
Electric Gas
No
HVAC
Rooftop Units or Packaged HVAC System
Electric Gas
No
HVAC
Smart Thermostat
Programmable and communicating thermostat
Electric Gas
Yes
HVAC
Split/Mini Split Air Conditioning Unit - Commercial
Electric
No
HVAC
Split/Mini Split Air Conditioning Unit - Residential In-Unit
18 SEER or above
Electric
No
HVAC
Static Pressure Reset
Electric Gas
No
HVAC
Steam Trap Audit/Replacement
Gas
No
HVAC
Variable Air Volume (VAV)
Electric Gas
No
HVAC
Variable Refrigerant Flow (VRF)
Electric Gas
No
HVAC
Ventilation Fan
Energy Star
Electric
No
HVAC
VFD on Compressor Motor
Electric
No
HVAC
VFD on Pump or Fan Motor
Electric
No
Industrial
Air Receiver Tanks for Load/No Load Compressor
Electric
No
Industrial
All-Electric Injection Molding Machine
Electric
No
Industrial
Compressed Air Cycling, Desiccant, or Heat Pump Dryer
Electric
No
Industrial
Compressed Air Leak Audit and Repair
Electric
No
Industrial
Compressed Air No-Loss Drain
Electric
No
Industrial
Compressed Air Pressure Reduction
Electric
Yes
Industrial
Energy Recovery Pressure Reducing Valve
Electric
No
Industrial
Exhaust Hood Control
Electric Gas
No
Industrial
High Performance Circulator Pump
Variable speed pump with ECM motor
Electric
No
Industrial
Notched or Synchronous Drive Belt
Electric
Yes
Industrial
Premium Efficiency Motor
NEMA Premium® rated motor
Electric
No
Industrial
Process Heat Recovery
Electric Gas
No
Industrial
Process Pump
Electric
No
Industrial
SCADA System
Electric Gas
No
Industrial
VFD on Compressor Motor
Electric
No
Industrial
VFD on Process Pump or Fan Motor
Electric
No
Lighting
Controls: Indoor Daylight Sensor
Wall or ceiling mount
Electric
No
Lighting
Controls: Indoor Networked Lighting System
DLC qualified Networked Lighting Control
Electric
No
Lighting
Controls: Indoor Vacancy Sensor
Wall or ceiling mount
Electric
No
Lighting
Controls: Integrated Networked Lighting System
DLC qualified Networked Lighting Control with Luminaire Level Lighting Control (LLLC)
Electric
No
Lighting
Controls: Integrated Vacancy and Daylight Sensor
Sensors are integral to the light fixture
Electric
No
Lighting
Controls: Integrated Vacancy Sensor
Sensors are integral to the light fixture
Electric
No
Lighting
Controls: Outdoor Networked Lighting System
DLC qualified Networked Lighting Control
Electric
No
Lighting
Controls: Outdoor Occupancy Sensor
Electric
No
Lighting
LED Accent/Track Light Fixture
Energy Star
Electric
No
Lighting
LED Case Light Fixture
DLC qualified display case, horizontal refrigerated case, or vertical refrigerated case
Electric
No
Lighting
LED Ceiling Mount or Pendant Fixture
Energy Star
Electric
No
Lighting
LED Decorative Screw-base Lamp
Energy Star
Electric
Yes
Lighting
LED Directional Screw-base Lamp
Energy Star
Electric
Yes
Lighting
LED Downlight Fixture
Energy Star hard-wired recessed, surface, or pendant mount
Electric
No
Lighting
LED Downlight Screw-base Retrofit Kit
Energy Star recessed or surface mount; screw base retrofit
Electric
Yes
Lighting
LED Four-Pin Replacement Lamp
DLC qualified vertical or horizontal lamps; UL type A
Electric
Yes
Lighting
LED General Service Screw-base Lamp
Energy Star
Electric
Yes
Lighting
LED High/Low-Bay Fixture or Retrofit Kit
DLC qualified high-bay, low-bay, or high-bay aisle
Electric
No
Lighting
LED Horticultural Hard-wired Light Fixture
DLC qualified horticultural light fixture (hard-wired)
Electric
No
Lighting
LED Horticultural Plug-in Light Fixture or Replacement Lamp
DLC qualified horticultural light fixture (plug-in) or replacement lamp
Electric
Yes
Lighting
LED Interior Directional Fixture
DLC qualified wall wash or track
Electric
No
Lighting
LED Linear Ambient Fixture or Retrofit Kit
DLC qualified direct or indirect linear
Electric
No
Lighting
LED Linear Replacement Lamp (TLED) - Type A
DLC qualified T8 or T5 linear replacement lamps (all dimensions); UL type A
Electric
Yes
Lighting
LED Linear Replacement Lamp (TLED) - Type B and C
DLC qualified T8 or T5 linear replacement lamps (all dimensions); UL types B and C
Electric
No
Lighting
LED Mogul Screw-base Replacement Lamp - Indoor
DLC qualified high- or low-bay; UL types B or C
Electric
No
Lighting
LED Mogul Screw-base Replacement Lamp - Outdoor
DLC qualified UL types B or C
Electric
No
Lighting
LED Outdoor Area Light Fixture or Retrofit Kit
DLC qualified pole/arm-mounted area, decorative, wall-mounted, bollards, parking garage, canopy, flood, spot, stairwell
Electric
No
Lighting
LED Residential-style Outdoor Wall, Porch, Post, or Security Light Fixture
Energy Star
Electric
No
Lighting
LED Street Light Fixture or Retrofit Kit
DLC qualified pole/arm-mounted roadway
Electric
No
Lighting
LED Tape Lighting
Electric
Yes
Lighting
LED Troffer Fixture or Retrofit Kit
DLC qualified 2x2, 1x4, or 2x4
Electric
No
Lighting
LED Under-Cabinet or Cove Fixture
Energy Star
Electric
No
Other
Building Management System (BMS)
Electric Gas
No
Other
Commercial Laundry - Clothes Washer (Electric Hot Water)
Energy Star
Electric
No
Other
Commercial Laundry - Clothes Washer (Gas Hot Water)
Energy Star
Gas
No
Other
Commercial Laundry - Dryer Moisture Sensor Retrofit (Electric)
Electric
No
Other
Commercial Laundry - Dryer Moisture Sensor Retrofit (Gas)
Gas
No
Other
Commercial Laundry - Modulating Gas Valve
Gas
No
Other
Commercial Laundry - Ozone System (Electric Hot Water)
Electric
No
Other
Commercial Laundry - Ozone System (Gas Hot Water)
Gas
No
Other
Energy Audit
Electric Gas
No
Other
Energy Management System (EMS)
Electric Gas
No
Other
Energy Measurement, Metering, or Monitoring Equipment
Must be installed with at least one other non-lighting Energy Savings Measure on this list
Electric Gas
Yes
Other
Generator Circulating Block Heater
Electric
No
Other
High Efficiency Distribution Transformer
Electric
No
Other
Other Measures Qualifying Through IOU/REN/CCA Programs
Measure not elsewhere on this list that qualifies for an IOU/REN/CCA energy efficiency or demand response program.
Electric Gas
No
Other
Other Measures Qualifying Through IOU/REN/CCA Programs - Self-Install
Measure not elsewhere on this list that qualifies for an IOU/REN/CCA energy efficiency or demand response program and for which the IOU/REN/CCA program allows self-install.
Electric Gas
Yes
Other
Plug Load Control
Electric
Yes
Pool Products
Gas Pool Water Heater
Gas
No
Pool Products
Heat Pump Pool Water Heater
Electric
No
Pool Products
Pool Cover (Electric Heater)
Electric
Yes
Pool Products
Pool Cover (Gas Heater)
Gas
Yes
Pool Products
Pool Pump Motor
Energy Star
Electric
No
Pool Products
VFD on Pool Pump Motor
Electric
No
Refrigeration
Add Doors to Open Case
Electric
Yes
Refrigeration
Add Insulation to Refrigerant Lines or Storage Tanks
Electric
Yes
Refrigeration
Air Curtain
Electric
No
Refrigeration
Anti-Condensation Door/Frame Heater Control
Electric
No
Refrigeration
Auto-Close Doors for Walk-in Cooler or Freezer
Electric
No
Refrigeration
Commercial Ice Machine
Energy Star
Electric
Yes
Refrigeration
Commercial Refrigerator or Freezer
Energy Star
Electric
Yes
Refrigeration
Compressor Unit
Electric
No
Refrigeration
Condensing Unit
Electric
No
Refrigeration
Evaporator Defrost Control for Freezer
Electric
No
Refrigeration
Evaporator Fan Brushless DC Motor
Electric
No
Refrigeration
Evaporator Fan Motor Control
Electric
No
Refrigeration
Evaporator Fan Permanent Magnet Synchronous Motor (PMSM)
Electric
No
Refrigeration
Floating Head Pressure Control
Electric
No
Refrigeration
Laboratory Grade Refrigerator or Freezer
Energy Star
Electric
No
Refrigeration
Low Charge Ammonia
Electric
No
Refrigeration
Low Energy Anti-Condensation Door
Electric
No
Refrigeration
Phase Change Material for Refrigerated or Freezer Storage
Electric
Yes
Refrigeration
Rapid Close Doors for Refrigerated Warehouse
Electric
No
Refrigeration
Reach-in Refrigerator or Freezer
Energy Star
Electric
No
Refrigeration
Refrigerated Case Door Strip
Electric
Yes
Refrigeration
Refrigerated Case Night Cover
Electric
Yes
Refrigeration
Refrigeration Tune-up and Optimization
Electric
No
Refrigeration
Vending Machines
Energy Star
Electric
Yes
Refrigeration
VFD on Refrigeration Pump or Fan Motor
Electric
No
Water Heating
Central Gas Domestic Water Heater or Boiler
Gas
No
Water Heating
Faucet Aerator
Electric Gas
Yes
Water Heating
Faucet Laminar Flow Restrictor
Electric Gas
Yes
Water Heating
Heat Pump Water Heater
Energy Star
Electric
No
Water Heating
Recirculating Hot Water Pump Control
Temperature sensor or time clock control
Electric
No
Water Heating
Shower Head - Low Flow
Electric Gas
Yes
Water Heating
Shower Thermostatic Valve
Electric Gas
No
Water Heating
Tank Insulation
Electric Gas
Yes
Water Heating
Tank Water Heater (Gas)
Energy Star
Gas
No
Water Heating
Tankless Water Heater (Electric)
Electric
No
Water Heating
Tankless Water Heater (Gas)
Energy Star
Gas
No
Water Heating
Water Pipe Insulation
Electric Gas
Yes

Credits

Note: Authority cited: Sections 26006 and 26009, Public Resources Code. Reference: Sections 26002, 26002.5, 26003, 26006, 26011 and 26040, Public Resources Code.
History
1. New section filed 12-17-2018 as a deemed emergency pursuant to Public Resources Code section 26009; operative 12-17-2018 (Register 2018, No. 51). A Certificate of Compliance must be transmitted to OAL by 6-17-2019 or emergency language will be repealed by operation of law on the following day.
2. New section refiled 6-11-2019 as a deemed emergency pursuant to Public Resources Code section 26009, including amendment of section and Note; operative 6-18-2019 (Register 2019, No. 24). A Certificate of Compliance must be transmitted to OAL by 9-16-2019 or emergency language will be repealed by operation of law on the following day.
3. New section refiled 9-12-2019 as a deemed emergency pursuant to Public Resources Code section 26009; operative 9-16-2019 pursuant to Government Code section 11343.4(b)(2) (Register 2019, No. 37). A Certificate of Compliance must be transmitted to OAL by 12-16-2019 or emergency language will be repealed by operation of law on the following day.
4. Certificate of Compliance as to 9-12-2019 order, including further amendments, transmitted to OAL 12-13-2019 and filed 1-21-2020; amendments operative 1-21-2020 pursuant to Government Code section 11343.4(b)(3) (Register 2020, No. 4).
5. Amendment of section and Note filed 7-19-2021 as an emergency; operative 7-19-2021 (Register 2021, No. 30). A Certificate of Compliance must be transmitted to OAL by 1-18-2022 or emergency language will be repealed by operation of law on the following day.
6. Amendment of section and Note refiled 12-30-2021 as a deemed emergency pursuant to Public Resources Code section 26009; operative 1-18-2022 (Register 2021, No. 53). A Certificate of Compliance must be transmitted to OAL by 4-18-2022 or emergency language will be repealed by operation of law on the following day.
7. Amendment of section and Note refiled as a deemed emergency pursuant to Public Resources Code section 26009; operative 4-18-2022 (Register 2022, No. 15). A Certificate of Compliance must be transmitted to OAL by 7-18-2022 or emergency language shall be repealed by operation of law on the following day.
8. Certificate of Compliance as to 4-18-2022 order, including amendment of listing of Premium Efficiency Motor, transmitted to OAL 7-12-2022 and filed 8-15-2022; amendments effective 8-15-2022 pursuant to Government Code section 11343.4(b)(3) (Register 2022, No. 33).
This database is current through 3/15/24 Register 2024, No. 11.
Cal. Admin. Code tit. 4, § 10092.14, 4 CA ADC § 10092.14
End of Document