§ 6573. Fire Extinguishing Equipment--Requirements.
14 CA ADC § 6573Barclays Official California Code of Regulations
14 CCR § 6573
§ 6573. Fire Extinguishing Equipment--Requirements.
TABLE 2 |
Minimum number of type B-I hand-portable fire extinguishers required1 |
Size of boat | Length, feet | Without fixed fire extinguishing system in machinery space | With fixed fire extinguishing system in machinery space |
Under 16 | 1 | 0 |
16 and over, but under 26 | 1 | 0 | |
26 and over, but under 40 | 2 | 1 | |
40 and over, but not over 65 | 3 | 2 |
1 One type B-II hand-portable fire extinguisher may be substituted for two type B-I hand-portable fire extinguishers.
TABLE 3 |
Gross tonnage | Minimum number of B-II hand- |
Over | Not over | portable fire extinguishers |
-- | 50 | 1 | |
50 | 100 | 2 | |
100 | 500 | 3 | |
500 | 1,000 | 6 | |
1,000 | -- | 8 |
Credits
Note: Authority cited: Section 652, Harbors and Navigation Code. Reference: Section 652, Harbors and Navigation Code.
History
1. Amendment filed 10-13-72; effective thirtieth day thereafter (Register 72, No. 42).
2. Amendment filed 1-18-77; effective thirtieth day thereafter (Register 77, No. 4).
3. Repealer of subsection (a)(1)(B) filed 10-31-83; effective thirtieth day thereafter (Register 83, No. 45).
4. Editorial correction of Note filed 10-11-85 (Register 85, No. 41).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 14, § 6573, 14 CA ADC § 6573
End of Document |