§ 2020.9. Application and Fee Requirements for Standard Plan Approvals.
25 CA ADC § 2020.9Barclays Official California Code of RegulationsEffective: April 1, 2024
Effective: April 1, 2024
25 CCR § 2020.9
§ 2020.9. Application and Fee Requirements for Standard Plan Approvals.
(2) Three (3) copies of the plans, specifications, and/or installation instructions, if applicable, and two (2) copies of the design calculations, when required, to substantiate the design. Specifications shall be shown on the plan. Design calculations shall be submitted separately from the plan sheet.
(6) When plans and specifications fail to comply with the requirements of this chapter, the enforcement agency shall notify the applicant in writing, stating in what respects the plans do not comply. The applicant shall correct the plans and/or specifications and resubmit them to the enforcement agency or withdraw them from consideration, forfeiting all submitted fees.
ACCESSORY BUILDING OR STRUCTURE | ||
1. Name of Manufacturer | ||
2. Standard Plan Approval No. _____ | ||
3. Designed for: | ||
_____lbs. per square foot roof live load | ||
_____lbs. per square foot horizontal wind load | ||
_____lbs. per square foot snow load | ||
_____lbs. per square foot floor live load | ||
_____lbs. per square foot wind uplift load | ||
4. Structure (may) (may not) be enclosed. | ||
Department of Housing and Community Development |
(9) The identification label of approval shall be either Type I, II, or III as specified in this section, each capable of a ten (10) year life expectancy when exposed to ordinary outdoor environments. Letters and numbers shall be bold Gothic or similar style, varied for emphasis, as large as space permits, with the minimum size being 5/64 inch. Wording shall be easily read and concise. Where permanent type adhesives are used on Type I, II, or III plates, adhesives shall have a minimum thickness of .004 inches and the plates shall be affixed to a relatively smooth surface.
Minimum size: one and one-half (1 ½ ) inches by three (3) inches by .020 inches thick net dimensions (inside fastener heads).
Material: Aluminum, brass or stainless steel etched, stamped, engraved, or embossed to 0.015-inch minimum depth differential, color anodized or enamel filled.
Minimum Size: .005 inch by one and one-half (1 ½ ) inches by three (3) inches.
Material: Aluminum foil etched or stamped to .001 inches minimum depth differential with color anodized background.
Minimum Size: .003 inches by one and one-half (1 ½ ) inches by three (3) inches.
Material: Aluminum/vinyl surface bonded (to be used for nameplates where variable information is required by embossing, which can be done with a conventional typewriter).
Minimum Size: .006 inches by one and one-half (1 ½ ) inches by three (3) inches.
(4) When the design of the system requires an engineering analysis of structural parts and methods of construction, such as required for an engineered tiedown system or engineered accessory building or structure, the plans, specifications, and calculations shall be signed by an architect or engineer.
(d) If an application or plans are incomplete or do not conform to this chapter, the applicant shall be notified in writing within ten (10) working days of the date they are received by the department. The applicant shall resubmit a corrected application or plans within ninety (90) days of the notice, or within ninety (90) days of any subsequent notification relating to a resubmittal, along with the fees required by Section 2020.9 of this section.
(j) A revised plan submitted pursuant to Section 2020.9 above, shall be processed as provided by subsection (h) or subsection (h) or subsection (i), depending upon whether or not the changes to the plan are substantive. A plan submitted after the final expiration shall be processed as a new application with appropriate fees assessed.
(m) Standard plan approval for each accessory building or structure, foundation system, or engineered tiedown system is contingent upon compliance with the requirements of this article. The department may conduct inspections to determine compliance with an approved plan. Violation of any of the provisions of this article or variations from an approved plan shall be cause for cancellation of the standard plan approval.
(p) The department shall be notified of any change in the name of an applicant or change in name or ownership of an applicant's business. The department may grant a standard plan approval to the new owner, if the new owner provides a written certification that the accessory building or structure foundation system or engineered tiedown system will be constructed in accordance with the existing standard plan approval and submits the completed form designated by the department, together with a ten dollar ($10) fee. The certification, application, and fee shall be submitted for each plan with a separate standard plan approval.
(r) Plans with a standard plan approval from the department shall be accepted by the enforcement agency as approved for the purpose of obtaining a construction permit if when the design loads and allowable soil conditions specified in the plans are consistent with the requirements for the locality. Local enforcement agencies shall not require the original signature or stamp of the architect or engineer on a standard plan approved by the department.
Credits
Note: Authority cited: Sections 18865, 18870.3 and 18871.3, Health and Safety Code. Reference: Sections 18870.2, 18870.3 and 18870.4, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
2. Amendment filed 12-29-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).
3. Amendment of subsection (r) filed 2-19-2013; operative 4-1-2013 (Register 2013, No. 8).
4. Amendment of subsection (b)(3), repealer and new subsection (b)(4) and amendment of subsections (b)(4)(A)-(B), (b)(9)(C) and (g) filed 2-27-2024; operative 4-1-2024 (Register 2024, No. 9).
This database is current through 8/30/24 Register 2024, No. 35.
Cal. Admin. Code tit. 25, § 2020.9, 25 CA ADC § 2020.9
End of Document |