Home Table of Contents

Appendix B Substance Technical Guidelines for Cadmium

8 CA ADC § 5207 App. BBarclays Official California Code of Regulations

Barclays California Code of Regulations
Title 8. Industrial Relations
Division 1. Department of Industrial Relations
Chapter 4. Division of Industrial Safety
Subchapter 7. General Industry Safety Orders
Group 16. Control of Hazardous Substances
Article 110. Regulated Carcinogens
8 CCR § 5207 App. B
Appendix B Substance Technical Guidelines for Cadmium
I. CADMIUM METAL
A. Physical and Chemical Data
1. Substance Identification
Chemical name: Cadmium
Formula: Cd
Molecular Weight: 112.4
Chemical Abstracts Service (CAS) Registry No.: 7740-43-9
Other Identifiers: RTECS EU9800000; EPA D006; DOT 2570 53
Synonyms: Colloidal Cadmium: Kadmium (German): CI 77180
2. Physical data
Boiling point: (760 mm Hg): 765 degrees C
Melting point: 321 degrees C
Specific Gravity: (H20=@ 20°c): 8.64
Solubility: Insoluble in water; soluble in dilute nitric acid and in sulfuric acid
Appearance: soft, blue-white, malleable, lustrous metal or grayish-white powder.
B. Fire, Explosion and Reactivity Data
1. Fire
Fire and Explosion Hazards: The finely divided metal is pyrophoric, that is the dust is a severe fire hazard and moderate explosion hazard when exposed to heat or flame. Burning material reacts violently with extinguishing agents such as water, foam, carbon dioxide, and halons.
Flash point: flammable (dust)
Extinguishing media: Dry sand, dry dolomite, dry graphite, or sodium chloride.
2. Reactivity
Conditions contributing to instability: Stable when kept in sealed containers under normal temperatures and pressure, but dust may ignite upon contact with air. Metal tarnishes in moist air.
Incompatibilities: Ammonium nitrate, fused: reacts violently or explosively with cadmium dust below 20°C. Hydrozoic acid: violent explosion occurs after 30 minutes. Acids: reacts violently, forms hydrogen gas. Oxidizing agents or metals: strong reaction with cadmium dust. Nitryl fluoride at slightly elevated temperature: glowing or white incandescence occurs. Selenium: reacts exothermically. Ammonia: corrosive reaction. Sulfur dioxide: corrosive reaction. Fire extinguishing agents (water, foam, carbon dioxide, and halons): reacts violently. Tellurium: incandescent reaction in hydrogen atmosphere.
Hazardous decomposition products: The heated metal rapidly forms highly toxic, brownish fumes of oxides of cadmium.
C. Spill, Leak and Disposal Procedures
1. Steps to be taken if the materials is released or spilled.
Do not touch spilled material. Stop leak if you can do it without risk. Do not get water inside container. For large spills, dike spill for later disposal. Keep unnecessary people away. Isolate hazard area and deny entry. The Superfund Amendments and Reauthorization Act of 1986 Section 304 requires that a release equal to or greater than the reportable quantity for this substance (1 pound) must be immediately reported to the local emergency planning committee, the state emergency response commission, and the National Response Center (800) 424-8802; in Washington, D.C. metropolitan area (202) 426-2675.
II. CADMIUM OXIDE
A. Physical and Chemical Data
1. Substance identification
Chemical name: Cadmium Oxide
Formula: Cd0
Molecular Weight: 128.4
CAS No.: 1306-19-0
Other Identifiers: RTECS EV1929500
Synonyms: Kadmu tlenek (Polish)
2. Physical data
Boiling point (760 mm Hg): 950 degrees C decomposes
Melting point: 15000C
Specific Gravity: (H20 = 1 @ 200C): 7.0
Solubility: Insoluble in water; soluble in acids and alkalines
Appearance: Red or brown crystals
B. Fire, Explosion and Reactivity Data
1. Fire
Fire and Explosion Hazards: Negligible fire hazard when exposed to heat or flame.
Flash point: Nonflammable
Extinguishing media: Dry chemical, carbon dioxide, water spray or foam.
2. Reactivity
Conditions contributing to instability: Stable under normal temperatures and pressures.
Incompatibilities: Magnesium may reduce CdO2 explosively on heating.
Hazardous decomposition products: Toxic fumes of cadmium.
C. Spill Leak and Disposal Procedures
1. Steps to be taken if the material is released or spilled.
Do not touch spilled material. Stop leak if you can do it without risk. For small spills, take up with sand or other absorbent material and place into containers for later disposal. For small dry spills, use a clean shovel to place material into clean, dry container and then cover. Move containers from spill area. For larger spills, dike far ahead of spill for later disposal. Keep unnecessary people away. Isolate hazard area and deny entry. The Superfund Amendments and Reauthorization Act of 1986 Section 304 requires that a release equal to or greater than the reportable quantity for this substance (1 pound) must be immediately reported to the local emergency planning committee, the state emergency response commission, and the National Response Center (800) 424-8802; in Washington, D.C. metropolitan area (202) 426-2675.
III. CADMIUM SULFIDE
A. Physical and Chemical Data
1. Substance Identification
Chemical name: Cadmium sulfide
Formula: CdS
Molecular weight: 144.5
CAS No. 1306-23-6
Other Identifiers: RTECS EV3150000
Synonyms: Aurora yellow; Cadmium Golden 366; Cadmium Lemon Yellow 527; Cadmium Orange; Cadmium Primrose 819; Cadmium Sulphide; Cadmium Yellow; Cadmium Yellow 000; Cadmium Yellow Conc. Deep; Cadmium Yellow Conc. Golden; Cadmium Yellow Conc. Lemon; Cadmium Yellow Conc. Primrose; Cadmium Yellow Oz. Dark; Cadmium Yellow Primrose 47-1400; Cadmium Yellow 10G Conc.; Cadmium Yellow 892; Cadmopur Golden Yellow N; Cadmopur Yellow: Capsebon; C.I. 77199; C.I. Pigment Orange 20; CI Pigment Yellow 37; Ferro Lemon Yellow; Ferro Orange Yellow; Ferro Yellow; Greenockite; NCI-C02711.
2. Physical data
Boiling point (760 mm. Hg): sublines in N2 at 980°C
Melting point: 1750 degrees C (100 atm)
Specific Gravity: (H20=1 @ 20°C): 4.82
Solubility: Slightly soluble in water; soluble in acid.
Appearance: Light yellow or yellow-orange crystals.
B. Fire, Explosion and Reactivity Data
1. Fire
Fire and Explosion Hazards: Negligible fire hazard when exposed to heat or flame.
Flash point: Nonflammable
Extinguishing media: Dry chemical, carbon dioxide, water spray or foam.
2. Reactivity
Conditions contributing to instability: Generally non-reactive under normal conditions. Reacts with acids to form toxic hydrogen sulfide gas.
Incompatibilities: Reacts vigorously with iodine monochloride.
Hazardous decomposition products: Toxic fumes of cadmium and sulfur oxides.
C. Spill Leak and Disposal Procedures
1. Steps to be taken if the material is released or spilled.
Do not touch spilled material. Stop leak if you can do it without risk. For small, dry spills, with a clean shovel place material into clean, dry container and cover. Move containers from spill area. For larger spills, dike far ahead of spill for later disposal. Keep unnecessary people away. Isolate hazard and deny entry.
IV. CADMIUM CHLORIDE
A. Physical and Chemical Data
1. Substance Identification
Chemical name: Cadmium chloride
Formula: CdC12
Molecular weight: 183.3
CAS No. 10108-64-2
Other Identifiers: RTECS EY0175000
Synonyms: Caddy; Cadmium dichloride; NA 2570 (DOT); UI-CAD; dichlorocadmium
2. Physical data
Boiling point (760 mm Hg): 960 degrees C
Melting point: 568 degrees C
Specific Gravity: (H20 = 1 @ 20°C): 4.05
Solubility: Soluble in water (140 g/100 cc); soluble in acetone.
Appearance: small, white crystals.
B. Fire, Explosion and Reactivity Data
1. Fire
Fire and Explosion Hazards: Negligible fire and negligible explosion hazard in dust form when exposed to heat or flame.
Flash point: Nonflammable
Extinguishing media: Dry chemical, carbon dioxide, water spray or foam.
2. Reactivity
Conditions contributing to instability: Generally stable under normal temperatures and pressures.
Incompatibilities: Bromine triflouride rapidly attacks cadmium chloride. A mixture of potassium and cadmium chloride may produce a strong explosion on impact.
Hazardous decomposition products: Thermal decomposition may release toxic fumes of hydrogen chloride, chloride, chlorine or oxides of cadmium.
C. Spill Leak and Disposal Procedures
1. Steps to be taken if the material is released or spilled.
Do not touch spilled material. Stop leak if you can do it without risk. For small, dry spills, with a clean shovel place material into clean, dry container and cover. Move containers from spill area. For larger spills, dike far ahead of spill for later disposal. Keep unnecessary people away. Isolate hazard and deny entry. The Superfund Amendments and Reauthorization Act of 1986 Section 304 requires that a release equal to or greater than the reportable quantity for this substance (100 pounds) must be immediately reported to the local emergency planning committee, the state emergency response commission, and the National Response Center (800) 424-8802; in Washington, D.C. Metropolitan area (202) 426-2675.
This database is current through 6/21/24 Register 2024, No. 25.
Cal. Admin. Code tit. 8, § 5207 App. B, 8 CA ADC § 5207 App. B