§ 1726.6.1. Pressure Testing Parameters.
14 CA ADC § 1726.6.1Barclays Official California Code of Regulations
14 CCR § 1726.6.1
§ 1726.6.1. Pressure Testing Parameters.
(5) The pressure test shall be continuous for one hour. A pressure test is successful if the pressure gauge does not show more than a 10 percent decline from the initial test pressure in the first 30 minutes, and does not show more than a 2 percent decline from the pressure after the first 30 minutes in the second 30 minutes.
Credits
Note: Authority cited: Sections 3013, 3106 and 3180, Public Resources Code. Reference: Sections 3106, 3180, 3181, 3220 and 3403.5, Public Resources Code.
History
1. New section filed 6-28-2018; operative 10-1-2018 (Register 2018, No. 26).