§ 2486. Ramada -- Permitted.
25 CA ADC § 2486Barclays Official California Code of Regulations
25 CCR § 2486
§ 2486. Ramada -- Permitted.
(e) A minimum of two (2) ventilating openings shall be installed at the highest point in the ramada roof to eliminate the buildup of products from vents or ducts. Vent openings shall be located near the ends of the ramada for cross-ventilation and shall have a minimum cross-sectional area of twenty-eight (28) square inches. Chimneys or vents of fuel burning appliances shall extend through the ramada roof surface and shall terminate in an approved roof jack and cap installed in accordance with the appliance listing and the manufacturer's installation instructions.
Credits
Note: Authority cited: Section 18865, Health and Safety Code. Reference: Sections 18871.3 and 18872, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 25, § 2486, 25 CA ADC § 2486
End of Document |