§ 2270. Sanitation Station Specifications.
25 CA ADC § 2270Barclays Official California Code of Regulations
25 CCR § 2270
§ 2270. Sanitation Station Specifications.
(a) Each recreational vehicle sanitation station shall be provided with a drain inlet not less than four (4) inches in diameter, discharging into a trap not more than twenty-four (24) inches below the drain inlet. The drain inlet shall be equipped with a hinged cover, which shall effectively close the drain inlet when not in use.
(c) The drain inlet of each recreational vehicle sanitation station shall be set in a concrete drain receptor not less than three and one-half (3 ½ ) inches in thickness and not less than two (2) feet horizontally from the drain inlet to the inside of the surrounding curb. The surrounding curb shall be at least four (4) inches wide and two (2) inches above the floor of the receptor. The inside surface of the drain receptor shall be smooth finished concrete and shall slope a minimum of one-fourth ( ¼ ) inch per foot from the bottom of the curb to the lip of the drain inlet.
(d) A three-quarter ( ¾ ) inch water hose connection shall be installed at each recreational vehicle sanitation station to allow connection of a hose for wash-down operation. A listed and approved backflow preventing vacuum breaker shall be permanently installed in the water service pipe at least six (6) inches above the highest point of usage. Provisions shall be made to store the wash-down hose off the ground.
Credits
Note: Authority cited: Section 18865.1, Health and Safety Code. Reference: Sections 18865.1, 18871.3, 18871.4 and 18873.1, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 25, § 2270, 25 CA ADC § 2270
End of Document |