§ 2216. Installation.
25 CA ADC § 2216Barclays Official California Code of Regulations
25 CCR § 2216
§ 2216. Installation.
(2) The conduit shall extend to a point not less than twelve (12) inches beyond any area where it is required to be installed, any potential source of ignition or area of confinement, or the outside wall of a building, and the outer ends of the conduit terminating underground shall be sealed. Where one (1) end of the conduit terminates within a building, unit, accessory building or structure, or building component, it shall be readily accessible and the space between the conduit and the gas piping shall be sealed to prevent leakage of gas into the building, unit, accessory building or structure, or building component.
(3) The space between the conduit and the service line must be sealed to prevent gas leakage into the building, unit, accessory building or structure, or building component, and, if the conduit is sealed at both ends, a vent line from the annular space must extend to a point where gas would not be a hazard, and extend above grade, terminating in a rain and insect resistant fitting.
Credits
Note: Authority cited: Sections 18865, 18865.05 and 18872, Health and Safety Code. Reference: Section 18873.4, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
2. Amendment of subsection (a) and Note filed 12-26-2006; operative 1-2-2007 pursuant to Government Code section 11343.4 (Register 2006, No. 52).
3. Amendment filed 1-21-2009; operative 1-21-2009 pursuant to Government Code section 11343.4 (Register 2009, No. 4).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 25, § 2216, 25 CA ADC § 2216
End of Document |