Home Table of Contents

§ 2211. LPG Tanks.

25 CA ADC § 2211Barclays Official California Code of Regulations

Barclays California Code of Regulations
Title 25. Housing and Community Development
Division 1. Housing and Community Development
Chapter 2.2. Special Occupancy Parks
Article 4. Fuel Gas Requirements
25 CCR § 2211
§ 2211. LPG Tanks.
(a) LPG tank installations in parks must conform to the provisions related to LPG tanks contained in Chapter 38 of the California Fire Code.
(b) Units designed and constructed with securely mounted tanks may be served by either the lot or mounted tanks, but not by both at the same time.
(c) A permit from the enforcement agency is required to install any LPG fuel tank exceeding sixty 60 U. S. gallons.
(d) LPG tanks shall be designed and constructed in accordance with nationally recognized standards for unfired pressure vessels.
(e) LPG tanks shall be securely, but not permanently, fastened to the mobilehome or recreational vehicle hitch or a substantial post to prevent accidental overturning.
(f) All LPG tanks located in a floodplain as designated by the local floodplain management agency, shall be securely anchored to prevent flotation.

Credits

Note: Authority cited: Section 18865, Health and Safety Code. Reference: Section 18873.4, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
2. Amendment of subsection (a) filed 1-21-2009; operative 1-21-2009 pursuant to Government Code section 11343.4 (Register 2009, No. 4).
3. New subsections (e) and (f) filed 2-18-2011; operative 2-18-2011 pursuant to Government Code section 11343.4 (Register 2011, No. 7).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 25, § 2211, 25 CA ADC § 2211
End of Document