§ 2180. Lot Service Equipment.
(d) Lot service equipment may also contain additional receptacles for supplying portable electrical equipment, provided that such receptacles are listed grounding-type receptacles. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets in lot service equipment shall be protected by ground-fault circuit protection. The requirement for ground-fault circuit protection shall not apply to equipment or installations constructed, installed, or approved for construction or installation prior to September 1, 1975.