§ 2163. Grounding of Units.
25 CA ADC § 2163Barclays Official California Code of Regulations
25 CCR § 2163
§ 2163. Grounding of Units.
All exposed, noncurrent-carrying metal parts of a unit, when connected to the lot service equipment, shall be grounded by means of a grounding conductor run with the circuit conductors or in a listed power supply cord provided with an approved polarized multi-prong plug. One prong of the plug shall be for the sole purpose of connecting that grounding conductor, by means of a listed and approved grounding receptacle, to the grounded terminal at the lot service. The conductor shall be insulated and identified by a green color.
Credits
Note: Authority cited: Section 18865, Health and Safety Code. Reference: Sections 18871 and 18873.3, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 25, § 2163, 25 CA ADC § 2163