Home Table of Contents

§ 1334.5. Footings on Uneven Surfaces.

25 CA ADC § 1334.5Barclays Official California Code of Regulations

Barclays California Code of Regulations
Title 25. Housing and Community Development
Division 1. Housing and Community Development
Chapter 2. Mobilehome Parks and Installations
Article 7. MH-Unit and Commercial Modular Installations and Facilities
25 CCR § 1334.5
§ 1334.5. Footings on Uneven Surfaces.
When footings span an uneven surface, one of the following methods shall be used to level the area of the footing:
(a) Placed on firm undisturbed soil or compacted fill pursuant to section 1334(d).
(b) Poured in place concrete at least three and one-half (3 ½ ) inches thick extending to the edge of the footing.
(c) Pressure-treated wood meeting the requirements of section 1334.
(d) Compacted class 2 aggregate with the level top footing surface extending a minimum 12 (12) inches beyond the edge of the footing.
(e) Fills for uneven surfaces exceeding six (6) inches in depth shall be made with poured in place concrete or alternate engineered method approved by the enforcement agency. The concrete shall have a minimum twenty-eight (28)-day compressive strength of not less than two-thousand-five-hundred (2500) pounds-per-square-inch.

Credits

Note: Authority cited: Sections 18300 and 18613, Health and Safety Code. Reference: Sections 18300 and 18613, Health and Safety Code.
History
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).
This database is current through 5/17/24 Register 2024, No. 20.
Cal. Admin. Code tit. 25, § 1334.5, 25 CA ADC § 1334.5
End of Document