§ 1262. Vent Location and Support.

25 CA ADC § 1262Barclays Official California Code of Regulations

Barclays California Code of Regulations
Title 25. Housing and Community Development
Division 1. Housing and Community Development
Chapter 2. Mobilehome Parks and Installations
Article 5. Plumbing Requirements
25 CCR § 1262
§ 1262. Vent Location and Support.
All vent pipes in outdoor locations shall be located at least ten (10) feet from an adjoining property line and shall extend at least ten (10) feet above ground level. All vent pipes shall be supported by at least the equivalent of a four (4) inch by four (4) inch nominal dimension redwood post securely anchored in the ground. One-piece galvanized iron vent pipes may be self-supporting if securely anchored at their base in concrete at least twelve (12) inches in depth and extending a minimum four (4) inches out from the pipe.

Credits

Note: Authority cited: Section 18300, Health and Safety Code. Reference: Section 18630, Health and Safety Code.