§ 2560. Field Training Facility.
19 CA ADC § 2560Barclays Official California Code of Regulations
19 CCR § 2560
§ 2560. Field Training Facility.
(F) One Chlorine Tank Dome designed for liquid line, vapor line and safety relief valve leak. One leak should be from vibration opening of valve, one leak from a valve loose in its mount, and one leak from a failed safety relief valve. The tank dome shall be designed to allow the student to read the vapor pressure via one of the vapor lines.
(2) Upon written request for FTF inspection from any FTF Coordinator, the California Specialized Training Institute Hazardous Materials Section Chief shall notify the Office of the State Fire Marshal Training Division to arrange for a joint inspection within 45 calendar days of receiving the FTF Coordinator's written request.
(3) The FTF Coordinator requesting the inspection shall be notified, in writing, by the California Specialized Training Institute Hazardous Materials Section as to the date and time for the FTF inspection. The FTF Coordinator shall arrange for the proper personnel to be at the FTF to operate equipment and demonstrate that the training aids function as required during the inspection.
(5) Inspectors shall ensure that all the minimum required equipment and training aids, as defined in Section 2560(a), are present and fully operational. Inspectors shall complete a Field Training Facility Inspection Report (HM form 190), as referenced in Section 2550 and forward it to the California Specialized Training Institute Hazardous Materials Section Chief within 10 working days. Within 10 working days of receiving the inspection report, the California Specialized Training Institute Hazardous Materials Section Chief shall notify the FTF Coordinator, in writing, that the inspected FTF has been approved or denied certification. If the FTF is disapproved, the Section Chief shall forward a written report to the FTF Coordinator specifying the inspected FTF's deficiencies. Once the FTF Coordinator has corrected all of the identified deficiencies, the FTF Coordinator may request another inspection pursuant to this section.
(7) Any State Certified FTF is subject to unannounced inspection/audits conducted by a faculty member of the California Specialized Training Institute Hazardous Materials Section and/or a designee of the Office of the State Fire Marshal. Unannounced FTF inspection/audits will be conducted in accordance with the procedures established in Section 2540(f).
(8) If any changes occur in the FTF minimum requirements, as referenced in Section 2560(a), then the Chief of the California Specialized Training Institute Hazardous Materials Section is required to notify all FTF Coordinators in writing of said changes within 30 working days. FTF Coordinators shall have 90 working days to make all said changes. Upon completing changes, the FTF Coordinator will notify the Chief of the California Specialized Training Institute Hazardous Materials Section in writing within 30 working days. The Chief of the California Specialized Training Institute Hazardous Materials Section may, at his or her discretion, initiate an FTF inspection to verify compliance with said changes. All changes shall be completed prior to any state certified courses being conducted at the FTF.
(3) All Course Managers conducting training at a FTF shall have received prior permission from the Field Training Facility Coordinator. The FTF Coordinator can deny use of the FTF to a Course Manager, if in the FTF Coordinator's opinion, the FTF is inadequately supplied, maintained, or presents any unsafe training conditions.
Credits
Note: Authority cited: Section 8574.20(a), Government Code. Reference: Section 8574.20(b), Government Code.
History
1. New section filed 5-12-94; operative 6-13-94 (Register 94, No. 19).
2. Amendment of section and Note filed 4-25-2003; operative 5-25-2003 (Register 2003, No. 17).
This database is current through 5/10/24 Register 2024, No. 19.
Cal. Admin. Code tit. 19, § 2560, 19 CA ADC § 2560
End of Document |