§ 3085.21. Suspension Means [Rule 1502.11].
8 CA ADC § 3085.21Barclays Official California Code of Regulations
Barclays California Code of Regulations
Title 8. Industrial Relations
Division 1. Department of Industrial Relations
Chapter 4. Division of Industrial Safety
Subchapter 6. Elevator Safety Orders
Group II. Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998 (Refs & Annos)
Article 12.3. Special Purpose Personnel Elevators
8 CCR § 3085.21
§ 3085.21. Suspension Means [Rule 1502.11].
(a) Suspension means shall consist of not less than two wire ropes. Only iron (low-carbon steel) or steel wire ropes having the commercial classification “Elevator Wire Rope,” or wire rope specifically constructed for elevator use, shall be used for the suspension of elevator cars and for the suspension of counterweights. The wire material for ropes shall be manufactured by the open-hearth or electric furnace process or their equivalent. [1502.11a]
(g) All wire ropes anchored to a winding drum shall have not less than one full turn of rope on the drum when the car or counterweight has reached its limit of possible over-travel, including a fully compressed buffer. Each turn of the wire rope on the winding drum shall be in a separate groove on the drum. [1502.11e]
Credits
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
This database is current through 6/7/24 Register 2024, No. 23.
Cal. Admin. Code tit. 8, § 3085.21, 8 CA ADC § 3085.21
End of Document |