§ 3085.7. Hoistway Doors and Gates [1500.6].
8 CA ADC § 3085.7Barclays Official California Code of Regulations
Barclays California Code of Regulations
Title 8. Industrial Relations
Division 1. Department of Industrial Relations
Chapter 4. Division of Industrial Safety
Subchapter 6. Elevator Safety Orders
Group II. Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998 (Refs & Annos)
Article 12.3. Special Purpose Personnel Elevators
8 CCR § 3085.7
§ 3085.7. Hoistway Doors and Gates [1500.6].
(a) Where hoistway doors or gates are required, the full width of each landing opening shall be protected to its full height, or 8 ft (2.44 m), whichever is less, by doors or gates. The entire entrance assembly shall be capable of withstanding a force of 250 lbs (113 kg) applied on the landing site at right angles to, and approximately at, the center of a panel. This force shall be distributed over an area of 4 in. (102 mm) by 4 in. (102 mm). There shall be no permanent displacement or deformation of any parts of the entrance assembly resulting from this test. Openwork entrances shall reject a ball 1 in. (25 mm) in diameter. [1500.6a]
Credits
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
History
1. Editorial correction of subsection (a) (Register 95, No. 34).
2. Editorial correction of subsection (f) (Register 95, No. 41).
This database is current through 6/7/24 Register 2024, No. 23.
Cal. Admin. Code tit. 8, § 3085.7, 8 CA ADC § 3085.7