§ 3085.4. Pits, Runby, and Top Clearances [Rule 1500.3].
8 CA ADC § 3085.4Barclays Official California Code of Regulations
Barclays California Code of Regulations
Title 8. Industrial Relations
Division 1. Department of Industrial Relations
Chapter 4. Division of Industrial Safety
Subchapter 6. Elevator Safety Orders
Group II. Elevator Installations for Which the Installation Contract Was Signed Before October 25, 1998 (Refs & Annos)
Article 12.3. Special Purpose Personnel Elevators
8 CCR § 3085.4
§ 3085.4. Pits, Runby, and Top Clearances [Rule 1500.3].
(d) There shall be a clearance of not less than 30 in. (762 mm) from the highest projection of the car top and/or the crosshead and the nearest part of the overhead structure, when the counterweight is resting on its fully compressed buffer. For rack and pinion elevators without counterweights, there shall be a clearance of not less than 30 in. (762 mm) from the highest projection of the car top and the nearest part of the overhead structure, when the car has reached the uppermost limit of its travel. [1500.3d]
Credits
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
History
1. Editorial correction of subsection (a)(4) (Register 95, No. 34).