Home Table of Contents

007.04.10-8. Flow Meters and Pressure Gauges

AR ADC 007.04.10-8Arkansas Administrative Code

West's Arkansas Administrative Code
Title 007. Department of Health
Division 04. Environmental Health Services
Rule 10. Rules Pertaining to Drip Dispersal Systems
Ark. Admin. Code 007.04.10-8
007.04.10-8. Flow Meters and Pressure Gauges
8.1 A flow meter shall be installed after the filter system but before the drip dispersal field. The flow meter shall incorporate not only a rate of flow gauge but also a total gallons pumped register. The flow rate gauge and total gallons pumped register may be separate devices. The flow meter shall be installed in a protective box that will be of sufficient size for servicing the meter and to allow easy access for reading the meter. The flow meter shall be sized for the dispersal flow as well as the additional field flushing volume.
8.2 Pressure gauges shall be located before the filter, after the filter and on the dispersal field return line. Pressure gauges shall be enclosed in the head works box, which allows easy access for observation. The gauges shall be liquid filled and a minimum of three (3) inches in diameter. The pressure range of the gauge shall be sufficient for the maximum pressure that will be expected in the system.

Credits

Adopted July 8, 2010.
Current with amendments received through February 15, 2024. Some sections may be more current, see credit for details.
Ark. Admin. Code 007.04.10-8, AR ADC 007.04.10-8
End of Document